Clinical Evaluation of a Novel CGM-Informed Bolus Calculator with Automatic Glucose Trend Adjustment
Jordan E Pinsker1,2, Mei Mei Church1,2, Sue A Brown3,2
1Sansum Diabetes Research Institute, Santa Barbara, California, USA.
Abstract:
Expert opinion guidelines and limited data from clinical trials recommend adjustment to bolus insulin doses based on continuous glucose monitor (CGM) trend data, yet minimal evidence exists to support this approach. We performed a clinical evaluation of a novel CGM-informed bolus calculator (CIBC) with automatic insulin bolus dose adjustment based on CGM trend used with sensor-augmented pump therapy. In this multicenter, outpatient study, participants 6-70 years of age with type 1 diabetes (T1D) used the Omnipod® 5 System in Manual Mode, first for 7 days without a connected CGM (standard bolus calculator, SBC, phase 1) and then for 7 days with a connected CGM using the CIBC (CIBC phase 2). The integrated bolus calculator used stored pump settings plus user-estimated meal size and/or either a manually entered capillary glucose value (SBC phase) or an imported current CGM value and trend (CIBC phase) to recommend a bolus amount. The CIBC automatically increased or decreased the suggested bolus amount based on the CGM trend. Twenty-five participants, (mean ± standard deviation) 27 ± 15 years of age, with T1D duration 12 ± 9 years and A1C 7.0% ± 0.9% completed the study. There were significantly fewer sensor readings <70 mg/dL 4 h postbolus with the CIBC compared to the SBC (2.1% ± 2.0% vs. 2.8 ± 2.7, P = 0.03), while percent of sensor readings >180 and 70-180 mg/dL remained the same. There was no difference in insulin use or number of boluses given between the two phases. The CIBC was safe when used with the Omnipod 5 System in Manual Mode, with fewer hypoglycemic readings in the postbolus period compared to the SBC. This trial was registered at ClinicalTrials.gov (NCT04320069).
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Dosage Regimen Designs: Nomograms and Tabulations
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...