Background:
Because impulse oscillometry (IOS) can detect changes in the small airways and is safer to perform during the COVID-19 pandemic than other pulmonary function tests, it may have value in investigating pulmonary sequelae in COVID-19 survivors. This study evaluated the performance of IOS in detecting lung abnormalities in COVID-19 survivors and investigated the associations of the findings with those of lung ultrasound (LUS) and spirometry.
Methods:
In this cross-sectional study, 117 subjects underwent IOS at a frequency range of 4-20 Hz 2 months after COVID-19 diagnosis. They also underwent spirometry and LUS, and their aeration scores were calculated.
Results:
On IOS, the resonance frequency was > 12 Hz, and the area under the reactance curve was > 3.60 cm H2O/L/s in 70 (59.8%) and 55 (47.0%) subjects, respectively. A heterogeneity of resistance between R4 and R20 (R4-R20) > 20% was observed in 60 (51.3%) participants. Based on their abnormalities in resistive and reactive parameters, 76 (65.0%) participants had abnormal IOS. Spirometry abnormalities were detected in 40 (34.2%) cases. LUS was abnormal in 51 (43.6%) participants, and the median aeration score was 0 (0-8) points. Abnormal IOS was associated with abnormal LUS (P < .001) and abnormal spirometry (P = .002). Abnormal spirometry had a significant but weaker association with abnormal LUS (P = .031). In participants who reported hospitalization, abnormal IOS was associated with both abnormal LUS (P = .001) and abnormal spirometry (P = .006). In participants who did not report hospitalization, abnormal IOS was associated with abnormal LUS (P < .001) but not abnormal spirometry (P = .063).
Conclusions:
In COVID-19 survivors, IOS detected changes even when spirometry was normal. In these individuals, IOS parameters were more strongly associated with abnormalities on LUS than with abnormalities on spirometry.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation