Related Experiment Video
Updated: Oct 21, 2025

Developing Photosensitizer-Cobaloxime Hybrids for Solar-Driven H2 Production in Aqueous Aerobic Conditions
Published on: October 5, 2019
An enhanced photoelectrochemical biosensor for colitoxin DNA based on HKUST-1/TiO2 and derived HKUST-CuO/TiO2
Delun Zheng1,2, Min Chen3, Jingjun Peng1
1Department of Chemistry and Laboratory for Preparation and Application of Ordered Structural Materials of Guangdong Province, Shantou University, Shantou, Guangdong, 515063, People's Republic of China.
Abstract:
HKUST-1 MOFs and its derivative HKUST-CuO were coupled with TiO2 nanoparticles to form the heterogeneous composites of HKUST-1/TiO2 and HKUST-CuO/TiO2 based on their well-suitable bandgap energies (Eg). Compared with mono-component HKUST-1 or HKUST-CuO, the prepared composites displayed photoelectrochemical (PEC) response due to the synergistic effect from their heterogeneous structure. Higher photocurrent response was obtained on HKUST-CuO/TiO2-modified ITO electrode (HKUST-CuO/TiO2/ITO), which could be attributed to the hollow structure with a thin shell of HKUST-CuO greatly enhancing visible spectra harvesting. The CuO component in HKUST-CuO not only could accelerate electron transfer on the heterojunction interface but also effectively separate the photo-generated charge carriers (e-1/h+). Based on the excellent PEC performance of prepared photoactive composite material, under visible-light excitation (λ ≥ 420 nm) and with a working potential of 0 V (vs. Ag/AgCl), the S1 (probe DNA)/HKUST-CuO/TiO2/ITO PEC platform was successfully fabricated for colitoxin DNA detection without using ascorbic acid (AA) as an electron donor. Compared with the analysis results on S1/HKUST-1/TiO2/ITO electrode, S1/HKUST-CuO/TiO2/ITO displayed a wider linear response range from 1.0 × 10-6 to 4.0 × 10-1 nM with a lower detection limit of 3.73 × 10-7 nM (S/N = 3), the linear regression equation was ΔI (10-6 A) =0.5549-0.1858 log (CS2/M), which confirmed the HKUST-CuO could improve sensitivity because of its prominent PEC property. The relative standard deviation (RSD) of the PEC sensor for target DNA detection of 2.0 × 10-4 nM was 7.4%. The proposed DNA biosensor also possessed good specificity and stability. Hence, this reported work was a promising strategy for molecular diagnosis in the bio-analysis field. (A) Schematic illustration of the preparation process of the proposed PEC biosensors for colitoxin DNA detection. (B) The preparation process of HKUST-1 and HKUST-CuO.

