Accuracy of Ultrasonography in Breast Implant Rupture Diagnosis: Systematic Review and Meta-Analysis
Ana Cristina Lacerda Macedo1, George Carvalho1, Maria L R Uggioni1
1From the Laboratory of Translational Biomedicine, Universidade do Extremo Sul Catarinense.
Background:
Breast augmentation is the most common aesthetic operation performed in the United States and worldwide; 1,862,506 breast augmentation procedures were performed in 2018, an increase of 27.6 percent compared to 2014 data.
Methods:
In the present study, the authors performed a systematic review to identify the accuracy of ultrasonography for diagnosing breast prosthesis rupture. Studies in which the ultrasound diagnostic test was compared to a surgical finding as a reference standard were reviewed.
Results:
As a result, 20 primary studies were included in the analyses, with a total of 1987 patients and 3297 prostheses. The use of ultrasound for diagnosis of breast prosthesis rupture presented the following results: pooled sensitivity, 73.7 percent (95 percent CI, 70.2 to 77.1 percent); pooled specificity, 87.8 percent (95 percent CI, 86.5 to 89.0); area under the receiver operating characteristic curve, 0.7762; diagnostic odds ratio, 11.04 (95 percent CI, 5.79 to 21.08).
Conclusion:
This study supports that ultrasound of breast prostheses is an adequate tool in the diagnosis of rupture.