Diffusivities of creatine phosphate and ATP in an aqueous solution studied by pulsed field gradient 31P NMR
Related Experiment Video
Updated: Sep 29, 2026

07:25
Use of Stopped-Flow Fluorescence and Labeled Nucleotides to Analyze the ATP Turnover Cycle of Kinesins
Published on: October 17, 2014
K Yoshizaki1, H Nishikawa, H Watari
1Department of Physiology, Kyoto Prefectural University of Medicine, Japan.
The Japanese Journal of Physiology
|January 1, 1987
Abstract:
The diffusivities of creatine phosphate and ATP were measured in an aqueous solution by pulsed field gradient 31P NMR. The diffusion coefficient of creatine phosphate was 1.4 times larger than that of ATP, suggesting the advantage of creatine phosphate in the energy transport in muscle cells.
More Related Videos
Related Concept Videos
Protein Diffusion in the Membrane
Proteins show rotational as well as lateral diffusion across the membrane. The lateral diffusion of proteins was confirmed through the cell fusion experiment where mouse and human cells were fused, resulting in hybrid cells. When the human and mouse cells fused, the specific membrane proteins on human and mouse cells were marked with the red and green-fluorescent markers, respectively. Initially, the red and green fluorescence was located on the respective hemisphere of the cell. As time...
ATP Driven Pumps I: An Overview
ATP-driven pumps, also known as transport ATPases, are integral membrane proteins. They have binding sites for ATP located on the membrane's cytosolic side and the ion-conducting domain in the transmembrane region. These pumps use the free energy released from ATP hydrolysis to move the solutes across cell membranes against an electrochemical gradient.
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and are...
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and are...
ATP Synthase: Mechanism
In animals, the mitochondrial F1F0 ATP synthase is the key protein that synthesizes ATP molecules through a complex catalytic mechanism. While the nuclear genome encodes the majority of ATP synthase subunits, the mitochondrial genome encodes some of the enzyme's most critical components. The formation of this multi-subunit enzyme is a complex multi-step process regulated at the level of transcription, translation, and assembly. Defects in one or more of these steps can result in decreased ATP...
The ADP/ATP Carrier Protein
ADP/ATP carrier or AAC protein is the most abundant carrier protein in the inner mitochondrial membrane. It transports large quantities of ADP and ATP, equivalent to the average human body weight, every day. Among other transporters, ACC protein is one of the best-studied members of the mitochondrial carrier protein family. The ADP/ATP carrier protein comprises two transmembrane helices connected to a loop and a single alpha-helix on the matrix side. It switches between two conformational...
ATP Driven Pumps III: V-type Pumps
V-type pumps are ATP-driven pumps found in the vacuolar membranes of plants, yeast, endosomal and lysosomal membranes of animal cells, plasma membranes of a few specialized eukaryotic cells, and some prokaryotes. They are also known as the V1Vo-ATPase, that couple ATP hydrolysis to transport protons against a concentration gradient.
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Protein Dynamics in Living Cells
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...