Related Experiment Video
Updated: Oct 21, 2025

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
A comparative study on the tip position of peripherally inserted central catheter inserted at two forward P-wave
Xinpeng Wang1, Yong Yang2, Jing Dong1
1Vascular Access Center (VAC), Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Bejing), Peking University Cancer Hospital & Institute, Beijing, China.
Background:
This study aimed to compare the tip location of peripherally inserted central catheter (PICC) under two forward P-wave amplitudes (P-wave amplitude is the autonomous peak or P-wave amplitude is 50-80% of the QRS main wave) by intracavitary electrocardiogram (IC-EKG) to determine the PICC tip in optimal location thus avoiding catheter-related complications.
Methods:
The data of 300 cancer patients with PICC insertion were collected retrospectively. For the observation group, the position of the catheter tip was left at the level when P wave amplitude was its autonomous peak (168 patients catheterized in 2018). While for the control group, the catheter tip was left at the level when the P wave amplitude was 50-80% of the QRS main wave (132 patients catheterized in 2017). Both groups of patients underwent the chest X-ray examination (CXR) after catheterization. The total compliance rate [PICC tip was located in the lower third of the Superior Vena Cava (SVC) and the Cavo-Atrial Junction (CAJ)], the optimal position compliance rate (PICC tip was located in the CAJ), and the incidence of the catheter tip malposition were compared between the two groups. The complications after catheterization including arrhythmia after catheterization within 24 hours, catheter-related thrombosis, catheter dysfunction, and catheter infection within 90 days were also compared.
Results:
There was no difference in the total compliance rate of PICC tip position and the incidence of the catheter malposition in the two groups (P>0.05). But the optimal position compliance rate of the observation group was higher than that of the control group (P<0.05). There was no difference in the incidence of arrhythmia after catheterization within 24 hours of the two groups (P>0.05). The incidence of catheter-related thrombosis, catheter dysfunction, and catheter infection within 90 days in the observation group was lower than those in the control group (P<0.05).
Conclusions:
The PICC tip position at the autonomous peak of the P wave is significantly better than that at the P wave amplitude being 50-80% of the QRS main wave under the IC-EKG guidance for PICC insertion.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Cardiac Catheterization IV: Nursing Management