Related Concept Videos

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

1.0K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.0K
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

8.1K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
8.1K
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

834
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
834
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

362
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
362
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

88
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
88
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

820
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
820

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A Sub-Microsecond Switch Enabling SWIFT <sup>23</sup>Na Imaging at 10.5 T.

Magnetic resonance in medicine·2026
Same author

An 80-channel receive array for 10.5T neuroimaging: Key considerations for SNR optimization.

bioRxiv : the preprint server for biology·2026
Same author

Mesoscale Whole-Brain T<sub>2</sub>*-Weighted and Associated Quantitative MRI in Humans at 10.5 T.

Magnetic resonance in medicine·2026
Same author

Modeling of Fiber Orientation-Dependent R1 Relaxation in Human White Matter In Vivo Within The Framework of The Transient Hydrogen Bond Model.

Magnetic resonance in medicine·2026
Same author

Consistent Quadratic Phase Formation in 3D Fast Spin Echo Using Frequency-Modulated RF Pulses.

Magnetic resonance in medicine·2026
Same author

A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils.

Magnetic resonance in medicine·2026
Same journal

Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

Magnetic resonance in medicine·2026
Same journal

A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp-Logan.

Magnetic resonance in medicine·2026
Same journal

7T 3D-EPI PCASL With High SNR Efficiency and Robustness to Through-Plane B<sub>0</sub> Field Gradients.

Magnetic resonance in medicine·2026
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
See all related articles

Related Experiment Video

Updated: Oct 21, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.7K

B1 -gradient-based MRI using frequency-modulated Rabi-encoded echoes.

Efraín Torres1,2, Taylor Froelich1, Paul Wang1,2

  • 1Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.

Magnetic Resonance in Medicine
|September 9, 2021
PubMed
Summary
This summary is machine-generated.

This study introduces frequency-modulated Rabi-encoded echoes (FREE), a new MRI technique that eliminates the need for pulsed field gradient hardware. FREE enables spatial encoding using radiofrequency fields, potentially reducing MRI costs and improving accessibility.

Keywords:
adiabatic full passagefrequency-modulatedportable MRIradiofrequency imagingsilent MRIsurface coil

More Related Videos

In vivo 19F MRI for Cell Tracking
10:05

In vivo 19F MRI for Cell Tracking

Published on: November 25, 2013

15.0K
Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.5K

Related Experiment Videos

Last Updated: Oct 21, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.7K
In vivo 19F MRI for Cell Tracking
10:05

In vivo 19F MRI for Cell Tracking

Published on: November 25, 2013

15.0K
Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.5K

Area of Science:

  • Magnetic Resonance Imaging
  • Radiofrequency Physics
  • Medical Imaging Technology

Background:

  • Conventional MRI relies on pulsed magnetic field gradients (B0) for spatial encoding, adding complexity and cost.
  • Existing radiofrequency (RF) imaging methods face limitations due to resonance offset and B1-gradient characteristics.

Purpose of the Study:

  • To develop and evaluate a novel RF imaging method for spatial encoding without B0 gradients.
  • To reduce the expense and increase the accessibility of MRI by eliminating hardware requirements.

Main Methods:

  • Introduced frequency-modulated Rabi-encoded echoes (FREE), an RF imaging technique using adiabatic full passage pulses and a B1 field gradient.
  • Implemented Cartesian phase encoding using FREE in a multi-shot double spin-echo sequence.
  • Conducted theoretical analysis, computer simulations, and experimental comparisons with conventional MRI on human visual cortex.

Main Results:

  • FREE enabled slice-selective 2D imaging of the human brain without a B0 gradient.
  • High resolution was achieved in areas with steep B1 gradients, while nonlinear B1 fields caused image distortions.
  • Minimal signal loss occurred due to B1 nonlinearities and resonance offset.

Conclusions:

  • Frequency-modulated Rabi-encoded echoes (FREE) is a viable method for MRI spatial encoding without B0 gradients.
  • Potential for future correction of image distortions using B1 and B0 maps.