GdDO3NI Enhanced Magnetic Resonance Imaging Allows Imaging of Hypoxia After Brain Injury
Babak Moghadas1, Vimala N Bharadwaj1, John P Tobey1
1School of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona, 85287-9709, USA.
Background:
Brain tissue hypoxia is a common consequence of traumatic brain injury (TBI) due to the rupture of blood vessels during impact and it correlates with poor outcome. The current magnetic resonance imaging (MRI) techniques are unable to provide a direct map of tissue hypoxia.
Purpose:
To investigate whether GdDO3NI, a nitroimidazole-based T1 MRI contrast agent allows imaging hypoxia in the injured brain after experimental TBI.
Study Type:
Prospective.
Animal Model:
TBI-induced mice (controlled cortical impact model) were intravenously injected with either conventional T1 agent (gadoteridol) or GdDO3NI at 0.3 mmol/kg dose (n = 5 for each cohort) along with pimonidazole (60 mg/kg) at 1 hour postinjury and imaged for 3 hours following which they were euthanized.
Field Strength/Sequence:
7 T/T2 -weighted spin echo and T1 -weighted gradient echo.
Assessment:
Injured animals were imaged with T2 -weighted spin-echo sequence to estimate the extent of the injury. The mice were then imaged precontrast and postcontrast using a T1 -weighted gradient-echo sequence for 3 hours postcontrast. Regions of interests were drawn on the brain injury region, the contralateral brain as well as on the cheek muscle region for comparison of contrast kinetics. Brains were harvested immediately post-imaging for immunohistochemical analysis.
Statistical Tests:
One-way analysis of variance and two-sample t-tests were performed with a P < 0.05 was considered statistically significant.
Results:
GdDO3NI retention in the injury region at 2.5-3 hours post-injection was significantly higher compared to gadoteridol (mean retention fraction 63.95% ± 27.43% vs. 20.68% ± 7.43% for gadoteridol at 3 hours) while it rapidly cleared out of the muscle region. Pimonidazole staining confirmed the presence of hypoxia in both gadoteridol and GdDO3NI cohorts, and the later cohort showed good agreement with MRI contrast enhancement.
Data Conclusion:
GdDO3NI was successfully shown to visualize hypoxia in the brain post-TBI using T1 -weighted MRI at 2.5-3 hours postcontrast.
Evidence Level:
1 TECHNICAL EFFICACY: Stage 1.
More Related Videos
05:52Early Pathological and Magnetic Resonance Detection of Cerebral Injury Using a Rat Model of Neonatal Hypoxic Ischemic Encephalopathy
Published on: October 28, 2022
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...