Related Experiment Video
Updated: Jun 18, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Balloon-Expandable versus Self-Expandable Valves in Transcatheter Aortic Valve Implantation: Complications and
Astrid C van Nieuwkerk1, Raquel B Santos1,2, Leire Andraka3
1Heart Center, Amsterdam UMC, Department of Cardiology, University of Amsterdam, Amsterdam Cardiovascular Sciences, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
Background:
Both balloon-expandable (BE) and self-expandable (SE) valves for transcatheter aortic valve implantation (TAVI) are broadly used in clinical practice. However, adequately powered randomized controlled trials comparing these two valve designs are lacking.
Methods:
The CENTER-study included 12,381 patients undergoing transfemoral TAVI. Patients undergoing TAVI with a BE-valve (n = 4096) were compared to patients undergoing TAVI with an SE-valve (n = 4096) after propensity score matching. Clinical outcomes including one-year mortality and stroke rates were assessed.
Results:
In the matched population of n = 5410 patients, the mean age was 81 ± 3 years, 60% was female, and the STS-PROM predicted 30-day mortality was 6.2% (IQR 4.0-12.4). One-year mortality was not different between patients treated with BE- or SE-valves (BE: 16.4% vs. SE: 17.0%, Relative Risk 1.04, 95%CI 0.02-1.21, p = 0.57). One-year stroke rates were also comparable (BE: 4.9% vs. SE: 5.3%, RR 1.09, 95%CI 0.86-1.37, p = 0.48).
Conclusion:
This study suggests that one-year mortality and stroke rates were comparable in patients with severe aortic valve stenosis undergoing TAVI with either BE or SE-valves.