Effect of changes in inspired oxygen fraction on oxygen delivery during cardiac surgery: a substudy of the CARROT trial
Related Experiment Video
Updated: Oct 20, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Karam Nam1, Hye-Bin Kim2, Young-Lan Kwak2
1Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, 03080, Korea.
When hemoglobin (Hb) is fully saturated with oxygen, the additional gain in oxygen delivery (DO2) achieved by increasing the fraction of inspired oxygen (FiO2) is often considered clinically insignificant. In this study, we evaluated the change in DO2, interrogated by mixed venous oxygen saturation (SvO2), in response to a change in FiO2 of 0.5 during cardiac surgery. When patients were hemodynamically stable, FiO2 was alternated between 0.5 and 1.0 in on-pump cardiac surgery patients (pilot study), and between 0.3 and 0.8 in off-pump coronary artery bypass grafting patients (substudy of the CARROT trial). After the patient had stabilized, a blood gas analysis was performed to measure SvO2. The observed change in SvO2 (ΔSvO2) was compared to the expected ΔSvO2 calculated using Fick's equation. A total 106 changes in FiO2 (two changes per patient; total 53 patients; on-pump, n = 36; off-pump, n = 17) were finally analyzed. While Hb saturation remained near 100% (on-pump, 100%; off-pump, mean [SD] = 98.1% [1.5] when FiO2 was 0.3 and 99.9% [0.2] when FiO2 was 0.8), SvO2 changed significantly as FiO2 was changed (the first and second changes in on-pump, 7.7%p [3.8] and 7.6%p [3.5], respectively; off-pump, 7.9%p [4.9] and 6.2%p [3.9]; all P < 0.001). As a total, regardless of the surgery type, the observed ΔSvO2 after the FiO2 change of 0.5 was ≥ 5%p in 82 (77.4%) changes and ≥ 10%p in 31 (29.2%) changes (mean [SD], 7.5%p [3.9]). Hb concentration was not correlated with the observed ΔSvO2 (the first changes, r = - 0.06, P = 0.677; the second changes, r = - 0.21, P = 0.138). The mean (SD) residual ΔSvO2 (observed - expected ΔSvO2) was 0%p (4). Residual ΔSvO2 was more than 5%p in 14 (13.2%) changes and exceeded 10%p in 2 (1.9%) changes. Residual ΔSvO2 was greater in patients with chronic kidney disease than in those without (median [IQR], 5%p [0 to 7] vs. 0%p [- 3 to 2]; P = 0.049). DO2, interrogated by SvO2, may increase to a clinically significant degree as FiO2 is increased during cardiac surgery, and the increase of SvO2 is not related to Hb concentration. SvO2 increases more than expected in patients with chronic kidney disease. Increasing FiO2 can be used to increase DO2 during cardiac surgery.
When hemoglobin (Hb) is fully saturated with oxygen, the additional gain in oxygen delivery (DO2) achieved by increasing the fraction of inspired oxygen (FiO2) is often considered clinically insignificant. In this study, we evaluated the change in DO2, interrogated by mixed venous oxygen saturation (SvO2), in response to a change in FiO2 of 0.5 during cardiac surgery. When patients were hemodynamically stable, FiO2 was alternated between 0.5 and 1.0 in on-pump cardiac surgery patients (pilot study), and between 0.3 and 0.8 in off-pump coronary artery bypass grafting patients (substudy of the CARROT trial). After the patient had stabilized, a blood gas analysis was performed to measure SvO2. The observed change in SvO2 (ΔSvO2) was compared to the expected ΔSvO2 calculated using Fick's equation. A total 106 changes in FiO2 (two changes per patient; total 53 patients; on-pump, n = 36; off-pump, n = 17) were finally analyzed. While Hb saturation remained near 100% (on-pump, 100%; off-pump, mean [SD] = 98.1% [1.5] when FiO2 was 0.3 and 99.9% [0.2] when FiO2 was 0.8), SvO2 changed significantly as FiO2 was changed (the first and second changes in on-pump, 7.7%p [3.8] and 7.6%p [3.5], respectively; off-pump, 7.9%p [4.9] and 6.2%p [3.9]; all P < 0.001). As a total, regardless of the surgery type, the observed ΔSvO2 after the FiO2 change of 0.5 was ≥ 5%p in 82 (77.4%) changes and ≥ 10%p in 31 (29.2%) changes (mean [SD], 7.5%p [3.9]). Hb concentration was not correlated with the observed ΔSvO2 (the first changes, r = - 0.06, P = 0.677; the second changes, r = - 0.21, P = 0.138). The mean (SD) residual ΔSvO2 (observed - expected ΔSvO2) was 0%p (4). Residual ΔSvO2 was more than 5%p in 14 (13.2%) changes and exceeded 10%p in 2 (1.9%) changes. Residual ΔSvO2 was greater in patients with chronic kidney disease than in those without (median [IQR], 5%p [0 to 7] vs. 0%p [- 3 to 2]; P = 0.049). DO2, interrogated by SvO2, may increase to a clinically significant degree as FiO2 is increased during cardiac surgery, and the increase of SvO2 is not related to Hb concentration. SvO2 increases more than expected in patients with chronic kidney disease. Increasing FiO2 can be used to increase DO2 during cardiac surgery.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
07:28Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...