Residual coracoclavicular separation after plate fixation for distal clavicle fractures: comparison between fracture
Ryogo Furuhata1,2, Noboru Matsumura2, Kazuhiko Udagawa2,3
1Department of Orthopaedic Surgery, National Hospital Organization Tokyo Medical Centre, Meguro-ku, Tokyo, Japan.
Background:
Plate fixation is an established treatment for Neer type II and V distal clavicle fractures; however, residual coracoclavicular (C-C) separation after osteosynthesis for unstable distal clavicle fractures has rarely been discussed. This study aimed to reveal the extent of postoperative C-C separation after plate fixation for distal clavicle fractures and to evaluate the relationship between residual C-C separation and the risk of postoperative complications.
Methods:
We retrospectively reviewed 60 patients with a displaced distal clavicle fracture that was treated with a Scorpion plate without C-C reconstruction and successfully united. Distal clavicle fractures were divided as per the Neer classification into type IIA (12 patients), IIB (36 patients), and V (12 patients) groups. The modified C-C distance ratio at the time of injury and after bone union, and the postoperative complications (plate-related pain, delayed union, infection, and contracture) were compared among the three groups.
Results:
The mean postoperative modified C-C distance ratio was 115.0% ± 12.0%; this ratio was significantly larger in the type IIB and V groups than in the type IIA group (P = .021 and P = .006, respectively). However, there was no significant difference in the frequency of postoperative complications among the three groups.
Conclusions:
Our study demonstrated that a certain degree of C-C separation remained after plate fixation for Neer type II and V distal clavicle fractures, even when bone union was achieved. The postoperative residual C-C separation was greater for the type IIB and V groups than for the type IIA group; however, this difference may not affect postoperative complications.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
04:01The Modified Single-working Portal Technique Using Lasso-loop Stitch with Needle for Arthroscopic Subscapularis Repair
Published on: August 8, 2025
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
