Related Experiment Video
Updated: Oct 20, 2025

A Novel Method: Super-selective Adrenal Venous Sampling
Published on: September 15, 2017
[The potential application of a three-dimensional visualization technique in adrenal vein sampling]
1Department of Urinary Surgery, Guizhou Provincial People's Hospital, Guiyang 550002, China.
Abstract:
Objective: To explore the potential application of a three-dimensional visualization technique in adrenal vein sampling (AVS). Methods: The clinical data were retrospectively analyzed, which included 76 patients with primary aldosteronism (PA) who have undergone AVS in Guizhou Provincial People's Hospital from December 2017 to May 2020. All cases were examined by adrenal thin-section enhanced CT and blood was drawn by bilateral AVS. Among them, the adrenal vein blood of 46 cases was sampled with the help of three-dimensional (3D) visualization processing of CT data, while that of 30 cases was without 3D visualization processing. The rate of the catheter in place, the successful rate of AVS, the time of blood collection, the dosage of the contrast agent, and surgical complications were compared between the two groups. Results: There were 76 cases included, while 38 were male and 38 were female. The average age was 45 (25-57) years. Compared with the patients without the aid of 3D visualization, the success rate of right AVS of the patients with the aid of 3D visualization technology increased from 43% to 78% (P<0.05). The success rate of adrenal vein blood collection increased from 53% to 83%. The dose of contrast agent decreased [the M(Q1,Q3) were78 (59, 89) ml vs 28 (16, 51) ml, P<0.05], and the time of blood sampling from the right adrenal vein approximately decreased [the M(Q1,Q3) were 70 (66, 88) min vs 44 (22, 61) min, P<0.05]. Compared with the case without the aid of 3D visualization, the left adrenal vein catheterization rate of patients in the 3D visualization group increased from 97% to 98%, the success rate of adrenal vein blood collection increased from 97% to 98%, and the differences of the time of blood sampling and the dosage of the contrast were not statistically significant between the two groups. Among all the cases experienced bilateral AVS, only one patient without 3D reconstruction had contrast extravasation, and the others had no obvious complications. Conclusions: Before AVS, 3D visualization processing of adrenal vein from CT data is capable of increasing the success rate of blood sampling from the right adrenal vein, as well as reducing the dosage of contrast agent and the time of adrenal vein blood sampling. Therefore, it has a potential clinical value of the application.
More Related Videos
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Anatomy of the Adrenal Glands
These glands possess a distinctive yellow tinge due to the stored cholesterol and fatty acids required for hormone synthesis. They are encased in a fibrous capsule and cushioned by fat.
The adrenal gland comprises two distinct...
Imaging Studies VII: Vascular Imaging