Related Experiment Video
Updated: Oct 20, 2025

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Challenges and Pitfalls of Using Repeat Spirometry Recordings in Routine Primary Care Data to Measure FEV1 Decline in
Hannah R Whittaker1, Steven J Kiddle2, Jennifer K Quint1
1National Heart and Lung Institute, Imperial College London, London, UK.
Background:
Electronic healthcare records (EHR) are increasingly used in epidemiological studies but are often viewed as lacking quality compared to randomised control trials and prospective cohorts. Studies of patients with chronic obstructive pulmonary disease (COPD) often use the rate of forced expiratory volume in 1 second (FEV1) decline as an outcome; however, its definition and robustness in EHR have not been investigated. We aimed to investigate how the rate of FEV1 decline differs by the criteria used in an EHR database.
Methods:
Clinical Practice Research Datalink and Hospital Episode Statistics were used. Patient populations were defined using 8 sets of criteria around repeated FEV1 measurements. At a minimum, patients had a diagnosis of COPD, were ≥35 years old, were current or ex-smokers, and had data recorded from 2004. FEV1 measurements recorded during follow-up were identified. Thereafter, eight populations were defined based on criteria around: i) the exclusion of patients or individual measurements with potential measurement error; ii) minimum number of FEV1 measurements; iii) minimum time interval between measurements; iv) specific timing of measurements; v) minimum follow-up time; and vi) the use of linked data. For each population, the rate of FEV1 decline was estimated using mixed linear regression.
Results:
For 7/8 patient populations, rates of FEV1 decline (age and sex adjusted) were similar and ranged from -18.7mL/year (95% CI -19.2 to -18.2) to -16.5mL/year (95% CI -17.3 to -15.7). Rates of FEV1 decline in populations that excluded patients with potential measurement error ranged from -79.4mL/year (95% CI -80.7 to -78.2) to -46.8mL/year (95% CI -47.6 to -46.0).
Conclusion:
FEV1 decline remained similar in a COPD population regardless of number of FEV1 measurements, time intervals between measurements, follow-up period, exclusion of specific FEV1 measurements, and linkage to HES. However, exclusion of individuals with questionable data led to selection bias and faster rates of decline.
More Related Videos
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-I: Introduction
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...

