Association Between Changes in Physical Activity and New-Onset Atrial Fibrillation After ICD/CRT-D Implantation
Xuerong Sun1, Shuang Zhao1, Keping Chen1
1Arrhythmia Center, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Abstract:
Background: Changes in physical activity (PA) after implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillators (CRT-D) implantation were unknown. The association of PA changes with new-onset atrial fibrillation (AF), cardiac death and all-cause mortality was unclear in patients at high risk of sudden cardiac death. Methods: Patients receiving ICD/CRT-D implantation from SUMMIT registry were retrospectively analyzed. Changes in PA were considered from baseline status to 1 year after implantation. New-onset AF was defined as the first atrial high-rate episode ≥1% of the daily AF burden detected after implantation. Results: Over a mean follow-up of 50.3 months, 124 new-onset AF events (36.2%), 61 cardiac deaths (17.8%), and 87 all-cause deaths (25.4%) were observed in 343 patients with ICD/CRT-D implantation. PA at 1 year after implantation was increased compared with PA at baseline (11.97 ± 5.83% vs. 10.82 ± 5.43%, P = 0.008), and PA at 1 year was improved in 210 patients (61.2%). Per 1% decrease in PA was associated with 12.4, 18.3, and 14.3% higher risks of new-onset AF, cardiac death and all-cause mortality, regardless of different baseline characteristics. Patients with decreased PA had 2-fold risks of new-onset AF (hazard ratio [HR] = 1.972, 95% confidence interval [CI]: 1.352-2.877, P < 0.001) as high as those with unchanged/increased PA. Decreased PA was an independent risk factor for cardiac death (HR = 3.358, 95% CI: 1.880-5.996, P < 0.001) and all-cause mortality (HR = 2.803, 95% CI:1.732-4.535, P < 0.001). Conclusion: PA decrease after ICD/CRT-D implantation is associated with a higher incidence of new-onset AF, resulting in worsened outcomes in cardiac death and all-cause mortality.
More Related Videos
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Acute Coronary Syndrome III: Diagnostic Studies