The effect of analytical temperature on thromboelastography tracings in dogs
Marie T Keith1, Nolan V Chalifoux1, Yekaterina Buriko1
1Department of Clinical Sciences and Advanced Medicine, Veterinary Hospital of the University of Pennsylvania, Philadelphia, PA, USA.
Abstract:
Viscoelastic testing methods such as thromboelastography (TEG) are becoming increasingly available to veterinarians in a clinical setting. TEG is useful in determining therapeutic transfusion needs and assessing global abnormalities of hemostasis of patients, given that it provides a more comprehensive assessment of coagulation than traditional tests. TEG is standardly performed at 37°C, which is considered a normal body temperature for human patients; however, 37°C is lower than normal body temperature for most canine patients. In an in vitro study, we investigated the potential effect that this difference in body temperature and test temperature might have on TEG results. Citrated blood samples were collected from clinically normal, as well as sick, dogs with various body temperatures. Samples were analyzed concurrently at the patient's body temperature and at 37°C. There was very high correlation between TEG performed at body temperature and at 37°C for R (min) and MA (mm), high correlation for K (min) and alpha angle (deg), and moderate correlation for LY30 (%) and LY60 (%). For canine patients with normal to mildly abnormal body temperatures, performance of TEG at the standard 37°C is acceptable.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...