Quantitative evaluation of single-photon emission computed tomography findings in lower extremity possible without
Tatsuya Tsuchitani1, Kazuhiro Kitajima2, Yoshiyuki Takahashi1
1Department of Radiological Technology, Hyogo College of Medicine College Hospital.
Objective:
For performing accurate quantitative analysis of single-photon emission computed tomography (SPECT)/computed tomography (CT) images, CT-based attenuation correction (CTAC) is considered to be necessary. However, the effect on quantitative values for an examined area close to the body surface, such as in the lower extremity, has yet to be elucidated. We performed the present investigation to determine the possibility of quantitative evaluation using a SPECT standalone device without CT.
Methods:
Validation was performed using clinical data of patients who underwent a lower extremity SPECT/CT examination, with grouping based on presence or absence of CTAC, scatter correction and resolution recovery. Using a reference group in which all types of correction were applied, standardized uptake values (SUVs), including maximum (SUVmax) and peak (SUVpeak), were examined in each group and compared.
Results:
As compared to the reference group, the difference in quantitative values became smaller in the order of the applied scatter correction and resolution recovery, applied resolution recovery, applied scatter correction, and neither scatter correction or resolution recovery applied groups, with no significant difference between the reference group and that with neither scatter correction or resolution recovery applied. A similar tendency was seen for both SUVmax and SUVpeak.
Conclusions:
In bone SPECT quantitative examinations of the lower extremity, quantitative evaluation without CTAC is possible without the use of scatter correction or resolution recovery. Thus, quantitative evaluation can be performed with use of a standalone SPECT device without CT.