Related Experiment Video
Updated: Oct 20, 2025

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Characterization of the vascular system using overnight wearable-based pulse arrival time and ambulatory blood
Jingyuan Hong1, Yali Zheng1, Shenghao Wu1
1College of Health Science and Environmental Engineering, Shenzhen Technology University, Shenzhen, China.
Abstract:
Pulse arrival time (PAT) has been broadly investigated for its potential for cuffless blood pressure (BP) estimation and ease of measurement by wearable devices. It is also of great significance to explore whether PAT conveys complementary information to BP for vascular health assessment. In this paper, the differences between the 24-h ambulatory BP and wearable-based PAT were compared among 12 young normotensives and 15 elderly hypertensives in terms of the mean and coefficients of variation (CoVs). The correlations of the nocturnal normalized PAT (n-PAT) and BP with two arterial stiffness-related parameters (i.e., the intrinsic elastic modulus E0 and the vascular modulation factor α) estimated by a proposed model-based method were also compared. The results showed that the inter-subject variances of the nocturnal average n-PAT were significantly different between the hypertensives and the normotensives (P < 0.001), and the intra-subject CoVs of the nocturnal n-PAT were also significantly different between the two groups (P < 0.05). However, these findings were not shown in the nocturnal BP. The correlation coefficient between the nocturnal average n-PAT and ln(E0) is larger than that with the nocturnal BP, i.e., 0.91 vs. 0.56. Furthermore, the result also revealed that all the hypertensives receiving antihypertensive medications did not achieve the optimal control of the nocturnal BP while presented diverse arterial stiffness indicated by the nocturnal average n-PAT and ln(E0). It is concluded that wearable-based PAT contains complementary information about the vascular system to the ambulatory BP, which may be useful for designing effective antihypertensive treatments.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Pulse
The pulse serves as a clinical...