Abdominal synthetic CT reconstruction with intensity projection prior for MRI-only adaptive radiotherapy
Sven Olberg1,2, Jaehee Chun3, Byong Su Choi1,3
1Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.
Abstract:
Objective. Owing to the superior soft tissue contrast of MRI, MRI-guided adaptive radiotherapy (ART) is well-suited to managing interfractional changes in anatomy. An MRI-only workflow is desirable, but producing synthetic CT (sCT) data through paired data-driven deep learning (DL) for abdominal dose calculations remains a challenge due to the highly variable presence of intestinal gas. We present the preliminary dosimetric evaluation of our novel approach to sCT reconstruction that is well suited to handling intestinal gas in abdominal MRI-only ART.Approach. We utilize a paired data DL approach enabled by the intensity projection prior, in which well-matching training pairs are created by propagating air from MRI to corresponding CT scans. Evaluations focus on two classes: patients with (1) little involvement of intestinal gas, and (2) notable differences in intestinal gas presence between corresponding scans. Comparisons between sCT-based plans and CT-based clinical plans for both classes are made at the first treatment fraction to highlight the dosimetric impact of the variable presence of intestinal gas.Main results. Class 1 patients (n= 13) demonstrate differences in prescribed dose coverage of the PTV of 1.3 ± 2.1% between clinical plans and sCT-based plans. Mean DVH differences in all structures for Class 1 patients are found to be statistically insignificant. In Class 2 (n= 20), target coverage is 13.3 ± 11.0% higher in the clinical plans and mean DVH differences are found to be statistically significant.Significance. Significant deviations in calculated doses arising from the variable presence of intestinal gas in corresponding CT and MRI scans result in uncertainty in high-dose regions that may limit the effectiveness of adaptive dose escalation efforts. We have proposed a paired data-driven DL approach to sCT reconstruction for accurate dose calculations in abdominal ART enabled by the creation of a clinically unavailable training data set with well-matching representations of intestinal gas.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography