Method development for optimizing analysis of ignitable liquid residues using flow-modulated comprehensive
Nadin Boegelsack1, Kevin Hayes2, Court Sandau3
1Department of Earth and Environmental Sciences, Mount Royal University, 4825 Mount Royal Gate SW, Calgary, AB Canada, T3E 6K6; Department of Civil, Geological and Environmental Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK Canada, S7N 5A9.
Abstract:
The abundance and composition of matrix compounds in fire debris samples undergoing ignitable liquid residue analysis frequently leads to inconclusive results, which can be diminished by applying comprehensive two-dimensional gas chromatography (GC × GC). Method development must be undertaken to fully utilize the potential of GC × GC by maximizing separation space and resolution.. The three main areas to consider for method development are column selection, modulator settings and parameter optimization. Seven column combinations with different stationary phase chemistry, column dimensions and orthogonality were assessed for suitability based on target compound selectivity, retention, resolution, and peak shapes, as well as overall peak capacity and area use. Using Box-Behnken design of experimentation (DoE), the effect of modulator settings such as flow ratio and loop fill capacity were evaluated using carbon loading potential, dilution effect, as well as target peak amplitude and skewing effect. The run parameters explored for parameter optimization were oven programming, inlet pressure (column flow rate), and modulation period. Comparing DoE approaches, Box-Behnken and Doehlert designs assessed sensitivity, selectivity, peak capacity, and wraparound; alongside target peak retention, resolution, and shape evaluation. Certified reference standards and simulated wildfire debris were used for method development and verification, and wildfire debris case samples scrutinized for method validation. The final method employed a low polarity column (5% diphenyl) coupled to a semi-polar column (50% diphenyl) and resulted in an average Separation Number (SN) exceeding 1 in both dimensions after optimization. Separation Numbers of 18.16 for first and 1.46 for second dimension without wraparound for compounds with at least four aromatic rings signified successful separation of all target compounds from varied matrix compositions and allowed for easy visual comparison of extracted ion profiles. Mass spectrometry (MS) was required during validation to differentiate ions where no baseline separation between target compounds and extraneous matrix compounds was possible. The resulting method was evaluated against ASTM E1618 and found to be an ideal routine analysis method providing great resolution of target compounds from interferences and excellent potential for ILR classification within a complex sample matrix.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...