Fluorescence-Activated Cell Sorting-Radioligand Treated Tissue FACS-RTT to Determine the Cellular Origin of Radioactive Signal
Published on: September 10, 2021
Unexpected (123I)FP-CIT SPECT findings: SWIDD, SWEDD and all DAT
Balestrino Roberta1,2, Barone Paolo3, Filippi Massimo4,5,6
1Department of Neurosurgery and Gamma Knife Radiosurgery, San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy.
Abstract:
Although the diagnosis of Parkinson's disease (PD) is essentially clinical, the implementation of imaging techniques can improve diagnostic accuracy. While some techniques (e.g. magnetic resonance imaging-MRI, computerized tomography-CT) are used to exclude secondary syndromes, presynaptic dopaminergic imaging including imaging of dopamine transporter (DAT)-can help the Neurologist in the differential diagnosis between neurodegenerative parkinsonian syndromes and parkinsonism without dopamine deficiency. DAT imaging can be useful in cases in which the clinical picture is not univocal, as in case of overlapping clinical features in patients with early disease, atypical syndromes or unsatisfying response to therapy. Currently, (123I)FP-CIT ([123I]N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane) (trade name DaTSCAN) is the only agent approved by international regulatory agencies for this purpose. With the increasing use of this technique, some unexpected findings have been reported, including patients clinically diagnosed with PD with a normal SPECT scan [e.g. Scans Without Evidence of Dopaminergic Deficit (SWEDD)]; PD patients with a greater dopaminergic deficit in the striatum ipsilateral to the clinically more affected side [e.g. Scans With Ipsilateral Dopaminergic Deficit (SWIDD)]; as well as some artifacts. Moreover, the neurologist must remember that structural lesions and administration of some drugs might alter the result of DAT imaging. Unexpected findings, artifacts, and misinterpretation of imaging findings can lead to an erroneous diagnosis and inappropriate therapy, neglect of other medical conditions that might explain the clinical picture, and undermine the selection phase in clinical trials. The aim of the present review is to bring clarity on these controversial (and sometimes erroneous) results, in order to inform of these possibilities the clinicians requesting a DaTSCAN in clinical practice.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...