Related Experiment Video
Updated: Oct 19, 2025

Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry SESI-MS
Published on: June 8, 2011
Quantification of volatile organic compounds by secondary electrospray ionization-high resolution mass spectrometry
Chao Liu1, Jiafa Zeng2, Pablo Sinues3
1Institute of Mass Spectrometry and Atmospheric Environment, Jinan University, Guangzhou, 510632, China.
Abstract:
Secondary electrospray ionization coupled with high resolution mass spectrometry (SESI-HRMS) is a direct mass spectrometry technique, which can identify trace volatile organic compounds (VOCs) in real time without sample pretreatment and chromatographic separation. SESI-HRMS has been successfully applied in multiple applications, including breath analysis, animals and plants VOCs emissions, analysis of headspace of cell cultures and indoor and outdoor air. The range of areas where the technique can potentially have a substantial impact is very broad. However, one critical aspect that requires further development to consolidate the technique is absolute quantification. Therefore, in this study we aim to develop a quantitative method for eight representative VOCs, including ketones (acetone, 2-butanone and 2-pentanone), alkenes (isoprene and α-terpinene) and aromatics (toluene, styrene and mesitylene). The mass spectrometric platform includes a commercial SESI source hyphenated with a Q-Exactive hybrid quadrupole Orbitrap high resolution mass spectrometer. Within the concentration range of 0-100 ppbv studied, the optimal coefficient of determination for linear regression (R2 = 0.993-0.999) between signal intensity and concentration is obtained in the range of 0-10 ppbv for all eight VOCs. The detection limits range between 3 (2-Pentanone) and 15 (Acetone) pptv. The intra-day (n = 10) and inter-day (n = 30) coefficients of variation (CV) are ≤ 6% and ≤10%, respectively. Finally the method is applied for the fast evaluation (<5 min) of different materials widely used for the collection, storage or pretreatment of gas sample. Better recovery of trace levels of eight VOCs is observed for PTFE gas sampling bag as compared to Nalophan and Tedlar bags; when Nafion tube is used to pretreat the gas sample, recovery of ≤50% are obtained for 2-pentanone, α-terpinene and all three aromatics.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Resolution Mass Spectrometry (HRMS)
Volatilization
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...