Related Experiment Video
Updated: Oct 19, 2025

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
One-View Time-of-Flight Positron Emission Tomography Reconstruction
1Utah Valley University, Orem, UT 84058 USA.
Abstract:
The time-of-flight (TOF) information makes Orlov's condition not necessary for positron emission tomography (PET) imaging. One-view imaging has never been attempted before. This paper investigates whether one-view imaging is possible. We claim that it is possible to obtain an image with measurements from only one-view, provided the TOF time resolution is good enough and the photon counts are high enough. In fact, the image value at a point can be reconstructed by measurements along one line-of-response (LOR) that passes through the point of interest. The region-of-interest (ROI) can be reconstructed with ray-by-ray deblurring methods, which make TOF PET a local tomography system. One-view imaging is a severely ill-posed problem if the TOF resolution is not good enough. One indicator of an ill-posed problem is the ringing artifacts in the reconstruction. We show that ringing artifacts can be eliminated by using the nonnegativity constraint for the dot-like objects with a zero background.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...