Related Experiment Video
Updated: Oct 19, 2025

Isolation and Characterization Of Chimeric Human Fc-expressing Proteins Using Protein A Membrane Adsorbers And A Streamlined Workflow
Published on: January 8, 2014
Profile of the single-use, multiple-pass protein A adsorber column in immunoadsorption
Nadine Schossee1, Gabriele Veit1, Julia Gittel1
1Institute of Transfusion Medicine and Haemotherapy, University of Wuerzburg, Wuerzburg, Germany.
Background And Objectives:
Immunoadsorptions (IA) are used to remove autoantibodies from the plasma in autoimmune disorders. In this study, we evaluated the effects of a single-use, recombinant staphylococcal protein A-based immunoadsorber on blood composition of the patient.
Materials And Methods:
In a cohort of patients with myasthenia gravis or stiff-person syndrome, essential parameters of blood cell count, coagulation, clinical chemistry or plasma proteins and immunoglobulins (Ig) were measured before and after IA (n = 11).
Results:
In average, IA reduced the levels of total IgG, IgG1, IgG2 and IgG4 by approximately 60%, the acetylcholine receptor autoantibody levels by more than 70%. IgG3, IgA or IgM were diminished to a lower extent. In contrast to fibrinogen or other coagulation factors, the column markedly removed vitamin K-dependent coagulation factors II, VII, IX and X by approximately 40%-70%. Accordingly, international normalized ratio and activated partial thromboplastin time were increased after IA by 59.1% and 32.7%, respectively. Coagulation tests almost returned to baseline values within 24 h. Blood cell count, electrolytes, total protein or albumin were not essentially affected. No clinical events occurred.
Conclusion:
The single-use, multiple-pass protein A adsorber column is highly efficient to remove IgG1, IgG2 and IgG4 or specific acetylcholine receptor autoantibodies from the plasma. Coagulation parameters should be monitored, since the column has the capacity to largely reduce vitamin K-dependent factors.
More Related Videos
07:53Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
10:08An Economical and Versatile High-Throughput Protein Purification System Using a Multi-Column Plate Adapter
Published on: May 21, 2021
Related Concept Videos
Affinity Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Analyte Adsorption and Distribution
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...