How biocompatible haemodialysers can conquer the need for systemic anticoagulation even in post-dilution
Floris Vanommeslaeghe1, Iván Josipovic2, Matthieu Boone2
1Department of Nephrology, Ghent University Hospital, Ghent, Belgium.
Background:
While systemic anticoagulation is most widely used in haemodialysis (HD), contraindications to its use might occur in particular settings. The Solacea™ haemodialyser with an asymmetric triacetate membrane claims improved biocompatibility and has already shown promising results when used in combination with only half dose of anticoagulation. To quantify the performance of the Solacea™ when further decreasing anticoagulation to zero, fibre blocking was assessed by micro-computed tomography (micro-CT).
Methods:
Ten maintenance HD patients underwent six dialysis sessions at midweek using a Solacea™ 19H dialyser, consecutively in pre-dilution haemodiafiltration (pre-HDF), HD and post-dilution HDF (post-HDF). After the first three sessions with only a quarter of their regular anticoagulation dose (one-quarter), the last three sessions were performed without anticoagulation (zero). Dialyser fibre blocking was quantified in the dialyser outlet potting using a 3D micro-CT scanning technique post-dialysis.
Results:
Even in case of reduced (one-quarter) anticoagulation, the relative number of open fibres post-dialysis was almost optimal, i.e. 0.96 (0.87-0.99) with pre-HDF, 0.99 (0.97-0.99) with HD and 0.97 (0.92-0.99) with post-HDF. Fibre patency was mildly decreased for pre-HDF and HD when anticoagulation was decreased from one-quarter to zero, i.e. to 0.76 (0.61-0.85) with pre-HDF (P = 0.004) and to 0.80 (0.77-0.89) with HD (P = 0.013). Comparing the results for zero anticoagulation, post-HDF [i.e. 0.94 (0.82-0.97)] performed as well as HD and pre-HDF.
Conclusions:
The Solacea™ dialyser provides promising results for use in conditions where systemic anticoagulation is contraindicated. Post-HDF, although inducing haemoconcentration in the dialyser, is equally effective for fibre patency in case of zero anticoagulation as pre-HDF and HD when using Solacea™.
More Related Videos
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
10:15The Use of the Ex Vivo Chandler Loop Apparatus to Assess the Biocompatibility of Modified Polymeric Blood Conduits
Published on: August 20, 2014
Related Concept Videos
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Dialysis
Continuous Renal Replacement Therapy