Related Experiment Video
Updated: Oct 19, 2025

Measuring Spray Droplet Size from Agricultural Nozzles Using Laser Diffraction
Published on: September 16, 2016
Analysis of droplet size uniformity and selection of spray parameters based on the biological optimum particle size
Chongchong Chen1, Shougen Li1, Xiaoyi Wu1
1School of Technology, Beijing Forestry University, Key Lab of State Forestry Administration for Forestry Equipment and Automation, Beijing, 10083, China.
Abstract:
Based on the theory of biological optimal particle size, the most easily attached droplets for different organisms have different particle sizes. To achieve the best average particle size, the droplet size in the atomization field must be more uniform and attain a high the adhesion rate. Therefore, during the application process, not only the average particle size of the droplets but also the influence of the uniformity of the droplets in the spray field must be considered. In this study, 20 small-angle fan nozzles ranging from 20° to 40° are used as the research objects. The droplet size information in the atomization field is obtained using a laser particle size analyzer, and the droplet uniformity under different parameters is calculated. The results showed that within the range of the parameters selected in the experiment, the droplet size increased with an increase in the flow rate, and decreased with an increase in the pressure. In addition, the angle had little effect on the droplet size. Increasing the spray height, spray angle, and pressure, while reducing the equivalent outlet diameter of the nozzle was beneficial to improve the uniformity of droplets. The order of the degree of influence of the four parameters on the uniformity of the droplets was height > equivalent outlet diameter (r) > pressure > spray angle, and the influence weights were 51.1%, 37.1%, 7.8%, 4.1%; 48.4%, 37.6%, 10%, and 4%. Under the condition of the parameter settings used in this experiment, the optimal atomization effect for the four intervals of 150-200 μm, 200-250 μm, 250-300 μm, and 300-400 μm was analyzed from the perspective of uniformity. The nozzle models with the best atomization effects in each interval were SS4003-0.3 MPa, SS4006-0.3 MPa, SS4008-0.3 MPa, and 633.512.30.CC-0.1 MPa.
Related Concept Videos
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Dose Size and Dosing Frequency: Determination Methods
Pipe Flowrate Measurement: Problem Solving

