Abstract

Insights

Formalin fixation decreases T1- and T2-values in postmortem (PM) MRI of the heart over time. These MRI signal changes correlate with reduced water content in fixed heart specimens.

Area of Science:

  • Forensic pathology
  • Medical imaging
  • Cardiovascular research

Background:

  • Postmortem magnetic resonance imaging (MRI) aids in determining cause of death.
  • Time constraints limit routine cardiac MRI application.
  • Previous studies analyzed formalin-fixed hearts, but fixation time effects on MRI values were unknown.

Purpose of the Study:

  • To investigate temporal changes in T1- and T2-values of cardiac MRI signals.
  • To assess signal variations in fresh, formalin-fixed, and sliced heart specimens.

Main Methods:

  • 21 autopsy cases (ages 9-92) were included.
  • Cardiac MRI scans were performed immediately post-excision, after formalin fixation, and post-slicing.
  • T1- and T2-values were calculated at each stage for 7 cases.

Main Results:

  • T1-values showed a decreasing trend from immediately after removal.
  • T2-values also decreased, with a more pronounced reduction observed in T1-values.
  • Formalin fixation progressively shortened T1- and T2-values over time.

Conclusions:

  • Formalin fixation significantly impacts cardiac MRI signal values.
  • T1- and T2-value shortening correlates with decreased water content in fixed hearts.
  • Approximation formulae were derived to quantify these time-dependent MRI signal changes.