Galvanic current dosage and bacterial concentration are determinants of the bactericidal effect of percutaneous

José Antonio García-Vidal1, Jesús Salinas2, Pilar Escolar-Reina3

  • 1Department of Physiotherapy, University of Murcia, Campus de Espinardo, 30100, Murcia, Spain. garciavidal@um.es.

Scientific Reports
|September 24, 2021
PubMed

Related Concept Videos

Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
383
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
345
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
233
Hand hygiene01:23

Hand hygiene

Asepsis is the practice of preventing or breaking the chain of infection. The nurse employs aseptic techniques to prevent the spread of microorganisms and reduce the risk of diseases. Hand hygiene is the cornerstone of aseptic techniques and is classified into medical and surgical asepsis. Medical asepsis includes hand hygiene and the use of gloves. Surgical asepsis, or the sterile technique, refers to practices that render and keep objects and areas free of microorganisms.
Hand washing...
4.6K