Related Experiment Video
Updated: Oct 19, 2025

Imaging and Quantification of the Hepatic Vasculature of Mice Using Ultrafast Doppler Ultrasound
Published on: July 19, 2024
Doppler ultrasound to assess the pharmacodynamic effects of splanchnic vasoactive compounds
Heleen Marynissen1, Thomas Lodeweyckx1, Didier Bielen2
1Center for Clinical Pharmacology, University Hospitals Leuven, Leuven, Belgium.
Aims:
In search of noninvasive biomarkers to assess the pharmacodynamic effects of portal pressure-lowering drugs, the reproducibility of flow measurements in the superior mesenteric artery was evaluated using Doppler ultrasound.
Methods:
A reproducibility study was conducted in 15 healthy male volunteers (18-50 y). Eight ultrasound measurements were performed for each subject: 2 observers each conducted 2 measurements during 2 separate visits. The following flow parameters were captured: peak systolic velocity (PSV), end diastolic velocity (EDV), pulsatility index (PI), volume flow (VF) and vessel diameter. Reproducibility was assessed by the intraclass correlation coefficient.
Results:
Results are presented as intraclass correlation coefficient [95% confidence interval]. The flow parameters PSV, EDV, PI and VF correlated excellently within observer during visit 1 (0.888 [0.748-0.953], 0.910 [0.793-0.962], 0.844 [0.656-0.933] and 0.916 [0.857-0.951], respectively) and visit 2 (0.925 [0.829-0.968], 0.942 [0.863-0.976], 0.883 [0.719-0.954] and 0.915 [0.855-0.951], respectively). Measurements conducted during 2 separate visits by 1 observer correlated well to excellently for PSV, EDV, PI and VF (0.756 [0.552-0.875], 0.836 [0.694-0.916], 0.807 [0.631-0.904] and 0.839 [0.783-0.882], respectively). Measurements conducted by 2 distinct observers correlated well to excellently for PSV, EDV and VF during visit 1 (0.813 [0.584-0.922], 0.884 [0.597-0.945] and 0.786 [0.575-0.899], respectively) and visit 2 (0.779 [0.498-0.912], 0.861 [0.672-0.945], 0.810 [0.553-0.926], respectively). Vessel diameter measurements were poorly reproducible.
Conclusion:
Doppler ultrasound is a reproducible method for flow measurements in the superior mesenteric artery in a standardized group of healthy volunteers. Therefore, it is a promising technique to assess pharmacodynamic effects of splanchnic vasoactive compounds in early clinical drug development.
More Related Videos
Related Concept Videos
Measurement of Bioavailability: Pharmacodynamic Methods
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Effect of Hepatic Disease on Pharmacokinetics: Drug Dosing and Hepatic Blood Flow
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...

