Related Experiment Video
Updated: Oct 19, 2025

14:14
Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
14.3K
Sutureless Versus Rapid Deployment Aortic Valve Replacement: Results From a Multicenter Registry.
Paolo Berretta1, Bart Meuris2, Utz Kappert3
1Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ospedali Riuniti, Ancona, Italy.
The Annals of Thoracic Surgery
|September 26, 2021
Summary
Sutureless vs. rapid deployment aortic valve replacement (SURD-AVR) showed similar safety and efficacy. The Perceval valve offered shorter operative times, while the Intuity valve demonstrated superior hemodynamics and less regurgitation.
Area of Science:
- Cardiovascular Surgery
- Medical Devices
- Clinical Outcomes
Background:
- Sutureless and Rapid Deployment Aortic Valve Replacement (SURD-AVR) represents an evolving approach to treating aortic valve disease.
- Large-scale registries are crucial for comparing clinical and hemodynamic outcomes of different SURD-AVR technologies.
Purpose of the Study:
- To compare the in-hospital clinical and hemodynamic outcomes of sutureless (Perceval) versus rapid deployment (Intuity) aortic valve replacement.
- To evaluate the safety and efficacy of these two SURD-AVR valve types in a large patient cohort.
Main Methods:
- Analysis of 4695 patients from the Sutureless and Rapid Deployment International Registry (SURD-IR).
- Propensity score matching created balanced cohorts for isolated (823 pairs) and combined (467 pairs) SURD-AVR.
- Comparison of clinical endpoints including mortality, complications, operative times, and hemodynamic parameters.
Main Results:
- Both Perceval and Intuity valves demonstrated similar in-hospital mortality and major complication rates.
- Perceval valve use was associated with shorter cross-clamp and cardiopulmonary bypass times.
- Intuity valve showed significantly lower postoperative transvalvular gradients and a reduced rate of mild aortic regurgitation.
Conclusions:
- Sutureless and Rapid Deployment Aortic Valve Replacement (SURD-AVR) is safe and effective, irrespective of the specific valve used.
- The Perceval valve is linked to reduced operative times and a higher likelihood of anterior right thoracotomy.
- The Intuity valve offers superior hemodynamic performance and a lower incidence of mild postoperative aortic regurgitation.