Related Experiment Video
Updated: Oct 19, 2025

Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Late Fontan failure in adult patients is predominantly associated with deteriorating ventricular function
Hannes Sallmon1, Stanislav Ovroutski2, Anastasia Schleiger2
1Department of Pediatric Cardiology, Charité - Universitätsmedizin Berlin, Germany; Department of Congenital Heart Disease/Pediatric Cardiology, German Heart Center Berlin, Germany.
Background:
The Fontan operation is a palliative procedure and a substantial number of patients eventually experiences late Fontan circulation failure. Previous concepts of Fontan failure implicate increasing pulmonary vascular resistance (PVR) as a key contributor to late circulatory failure. However, data to support this assumption are sparse. We sought to characterize longitudinal hemodynamic and echocardiographic findings in adult failing Fontan patients.
Methods:
We performed a retrospective cohort study in adult Fontan patients, identifying patients with Fontan failure. Hemodynamic, echocardiographic and clinical data were recorded.
Results:
Of 173 adult patients (median follow-up after Fontan 20.2 years [IQR 15.7-24.3]), 48 (28%) showed signs of clinical Fontan failure. Thirty-seven patients (77.1%) exhibited ventricular dysfunction (systolic dysfunction defined by ejection fraction ≤45%, n = 22, or diastolic dysfunction defined by systemic ventricular end-diastolic pressure (SVEDP) ≥12 mmHg, n = 15). Elevated indexed PVR (≥2.5 WU*m2) was only observed in 9 (18.8%) patients. Ejection fraction declined from 60% [IQR 55-65] to 47% [IQR 35-55] during follow-up (p < 0.001). Mean pulmonary artery pressure and SVEDP increased from 11 mmHg [IQR 9-15] to 15 mmHg [IQR 12-18] and from 7 mmHg [IQR 4-10] to 11 mmHg [IQR 8-15] (both p < 0.001), respectively, while indexed PVR did not change significantly (2.1 [IQR 1.1-2.4] vs. 1.7 [IQR 1.1-2.5] WU*m2, p = 0.949). Fontan failure-associated mortality during follow-up was substantial (23/48; 48%).
Conclusions:
Systolic and diastolic ventricular dysfunction are frequent features in late Fontan failure in adults, while increases in PVR were rarely observed. The intricate interplay between hemodynamic compromises in Fontan failure deserves further research to optimize treatment strategies and outcome.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery ALCAPA
Published on: April 24, 2017
Related Concept Videos
Heart Failure II: Pathophysiology
Mitral Regurgitation I: Introduction
Heart Failure I: Introduction
Mitral Stenosis I: Introduction
Pathophysiology of Heart Failure
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...