Related Experiment Video
Updated: Oct 19, 2025

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Validity, reliability, and responsiveness of daily monitoring visual analog scales in MASK-air®
Bernardo Sousa-Pinto1,2,3, Patrik Eklund4, Oliver Pfaar5
1MEDCIDS - Department of Community Medicine, Information and Health Decision Sciences Faculty of Medicine, University of Porto Porto Portugal.
Background:
MASK-air® is an app that supports allergic rhinitis patients in disease control. Users register daily allergy symptoms and their impact on activities using visual analog scales (VASs). We aimed to assess the concurrent validity, reliability, and responsiveness of these daily VASs.
Methods:
Daily monitoring VAS data were assessed in MASK-air® users with allergic rhinitis. Concurrent validity was assessed by correlating daily VAS values with those of the EuroQol-5 Dimensions (EQ-5D) VAS, the Control of Allergic Rhinitis and Asthma Test (CARAT) score, and the Work Productivity and Activity Impairment Allergic Specific (WPAI-AS) Questionnaire (work and activity impairment scores). Intra-rater reliability was assessed in users providing multiple daily VASs within the same day. Test-retest reliability was tested in clinically stable users, as defined by the EQ-5D VAS, CARAT, or "VAS Work" (i.e., VAS assessing the impact of allergy on work). Responsiveness was determined in users with two consecutive measurements of EQ-5D-VAS or "VAS Work" indicating clinical change.
Results:
A total of 17,780 MASK-air® users, with 317,176 VAS days, were assessed. Concurrent validity was moderate-high (Spearman correlation coefficient range: 0.437-0.716). Intra-rater reliability intraclass correlation coefficients (ICCs) ranged between 0.870 (VAS assessing global allergy symptoms) and 0.937 (VAS assessing allergy symptoms on sleep). Test-retest reliability ICCs ranged between 0.604 and 0.878-"VAS Work" and "VAS asthma" presented the highest ICCs. Moderate/large responsiveness effect sizes were observed-the sleep VAS was associated with lower responsiveness, while the global allergy symptoms VAS demonstrated higher responsiveness.
Conclusion:
In MASK-air®, daily monitoring VASs have high intra-rater reliability and moderate-high validity, reliability, and responsiveness, pointing to a reliable measure of symptom loads.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
06:57Effects of Surgical Masks on Cardiopulmonary Function in Healthy Subjects
Published on: February 12, 2021
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Strategies of Self-Presentation III: Self-Monitoring