Related Experiment Video
Updated: Oct 18, 2025

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Prediction of arterial blood pressure waveforms from photoplethysmogram signals via fully convolutional neural
Juan Cheng1, Yufei Xu2, Rencheng Song2
1Department of Biomedical Engineering, Hefei University of Technology, Hefei, 230009, China; Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, Hefei University of Technology, Hefei, 230009, China.
Abstract:
Cardiovascular disease (CVD) is one of the most serious diseases threatening human health. Arterial blood pressure (ABP) waveforms, containing vivid cardiovascular information, are of great significance for the diagnosis and the prevention of CVD. This paper proposes a deep learning model, named ABP-Net, to transform photoplethysmogram (PPG) signals into ABP waveforms that contain vital physiological information related to cardiovascular systems. In order to guarantee the quality of the predicted ABP waveforms, the structure of the network, the input signals and the loss functions are carefully designed. Specifically, a Wave-U-Net, one kind of fully convolutional neural networks (CNN), is taken as the core architecture of the ABP-Net. Besides the original PPG signals, its first derivative and second derivative signals are all utilized as the inputs of the ABP-Net. Additionally, the maximal absolute loss, accompany with the mean squared error loss is employed to ensure the match of the predicted ABP waveform with the reference one. The performance of the proposed ABP network is tested on the public MIMIC II database both in subject-dependent and subject-independent manners. Both results verify the superior performance of the proposed model over those existing methods accordingly. The mean absolute error (MAE) and the root-mean-square error (RMSE) between the predicted waveforms via the ABP-Net and the reference ones are 3.20 mmHg and 4.38 mmHg during the subject-dependent experiments while those are 5.57 mmHg and 7.15 mmHg during the subject-independent experiments. Benefiting from the predicted high-quality ABP waveforms, more ABP related physiological parameters can be better obtained, which effectively expands the application scope of PPG devices.
More Related Videos
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)

