Related Experiment Video
Updated: Oct 18, 2025

Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Global haemostatic tests demonstrate the absence of parameters of hypercoagulability in non-hypoxic mild COVID-19
Bingwen Eugene Fan1,2,3,4, Kollengode Ramanathan5,6, Christina Lai Lin Sum7
1Department of Haematology, Tan Tock Seng Hospital, Singapore, Singapore. Bingwen_Eugene_Fan@ttsh.com.sg.
Abstract:
Severe COVID-19 patients demonstrate hypercoagulability, necessitating thromboprophylaxis. However, less is known about the haemostatic profile in mild COVID-19 patients. We performed an age and gender-matched prospective study of 10 severe and 10 mild COVID-19 patients. Comprehensive coagulation profiling together with Thromboelastography and Clot Waveform Analysis were performed. FBC, PT, APTT, D-dimer, fibrinogen and CWA were repeated every 3 days for both groups and repeat TEG was performed for severe patients up till 15 days. On recruitment, severe patients had markers reflecting hypercoagulability including raised median D-dimer 1.0 μg/mL (IQR 0.6, 1.4) (p = 0.0004), fibrinogen 5.6 g/L (IQR 4.9, 6.6) (p = 0.002), Factor VIII 206% (IQR 171, 203) and vWF levels 265.5% (IQR 206, 321). Mild patients had normal values of PT, aPTT, fibrinogen and D-dimer, and slightly elevated median Factor VIII and von Willebrand factor (vWF) levels. Repeated 3-day assessments for both groups showed declining trends in D-dimer and Fibrinogen. CWA of severe COVID-19 group demonstrated hypercoagulability with an elevated median values of aPTT delta change 78.8% (IQR 69.8, 85.2) (p = 0.001), aPTT clot velocity (min1) 7.8%/s (IQR 6.7, 8.3) (p = 0.001), PT delta change 22.4% (IQR 19.4, 29.5) (p = 0.004), PT min1 7.1%/s (IQR 6.3, 9.0) (p = 0.02), PT clot acceleration (min 2) 3.6%/s2 (IQR 3.2, 4.5) (p = 0.02) and PT clot deceleration (max2) 2.9%/s2 (IQR 2.5, 3.5) (p = 0.02). TEG of severe patients reflected hypercoagulability with significant increases in the median values of CFF MA 34.6 mm (IQR 27.4,38.6) (p = 0.003), CRT Angle 78.9° (IQR 78.3, 80.0) (p = 0.0006), CRT A10 67.6 mm (IQR 65.8, 69.6) (p = 0.007) and CFF A10 32.0 mm (IQR 26.8, 34.0) (p = 0.003). Mild COVID-19 patients had absent hypercoagulability in both CWA and TEG. 2 severe patients developed thromboembolic events while none occurred in the mild COVID-19 group. Mild COVID-19 patients show absent parameters of hypercoagulability in global haemostatic tests while those with severe COVID-19 demonstrated parameters associated with hypercoagulability on the global haemostatic tests together with raised D-Dimer, fibrinogen, Factor VIII and vWF levels.
More Related Videos
04:56Author Spotlight: Deciphering Coagulation Disorders in Traumatic Brain Injury Patients
Published on: August 4, 2023
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Controls in Experiments
Coagulation
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
Introduction to Hemostasis
The three phases of hemostasis involve many clotting factors present in plasma and several substances released by platelets and injured tissue cells. It is a fast, localized,...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...