The effect of postoperative anticoagulation on false lumen patency after surgery for acute type A aortic dissection
Mårten Larsson1, Gracijela Bozovic2, Johan Sjögren3
1Department of Clinical Sciences Lund, Cardiothoracic Surgery, Lund University and Skåne University Hospital, Getingevägen 4, 221 85, Lund, Sweden. marten.larsson@med.lu.se.
Background:
Patent false lumen has been shown to have a negative impact on prognosis after surgery for acute type A aortic dissection (ATAAD). We aimed to assess the effect of postoperative anticoagulation on false lumen patency and clinical outcomes in relation to false lumen status.
Methods:
Postoperative computed tomographies of 156 patients undergoing ATAAD DeBakey type I surgery were retrospectively evaluated for false lumen patency. The patients were divided into groups determined by anticoagulation treatment at discharge. Uni- and multivariable logistic regression was used for analysing the effect of anticoagulation on the false lumen, and Kaplan-Meier estimates were used to assess the association of a patent false lumen with the incidence of reoperation and long-term survival.
Results:
A patent false lumen was present in 81% of the patients. Postoperative anticoagulants were not associated with a patent false lumen (p = 0.48) in univariable analysis. In multivariable analysis, both hemiarch replacement (OR 0.15, CI95% 0.05-0.49, p = 0.001) and the use of betablockers had a protective effect (OR 0.29, CI95% 0.10-0.85, p = 0.023). The Kaplan-Meier estimates for survival and the composite endpoint of survival and freedom from distal reintervention indicated no difference in outcome between patients in regard to anticoagulation treatment (survival p = 0.43, composite p = 0.82) or false lumen status (survival p = 0.21, composite p = 0.09).
Conclusion:
This study could not show negative effects from the postoperative use of anticoagulants on false lumen status, nor that false lumen patency was associated with poorer prognosis. A hemiarch procedure was shown to be associated with reduced risk of false lumen patency.