Related Experiment Video
Updated: Oct 18, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Comparison of Low-Energy and Medium-Energy Collimators for Thyroid Scintigraphy with 123I
Yuxin Li1, Esther Choi2, Artineh Hayrapetian3
1Department of Radiology, VA Greater Los Angeles Healthcare System, Los Angeles, California.
Abstract:
CE credit: For CE credit, you can access the test for this article, as well as additional JNMT CE tests, online at https://www.snmmilearningcenter.org Complete the test online no later than March 2025. Your online test will be scored immediately. You may make 3 attempts to pass the test and must answer 75% of the questions correctly to receive Continuing Education Hour (CEH) credit. Credit amounts can be found in the SNMMI Learning Center Activity. SNMMI members will have their CEH credit added to their VOICE transcript automatically; nonmembers will be able to print out a CE certificate upon successfully completing the test. The online test is free to SNMMI members; nonmembers must pay $15.00 by credit card when logging onto the website to take the test.123I thyroid scintigraphy can be performed with either a low-energy or a medium-energy (ME) collimator. The high-energy photon emissions from 123I cause septal penetration with scattered photons, which deteriorate image quality. The aim of this study was to evaluate the impact of collimator choice on 123I thyroid scintigraphy in clinical practice. Methods: Forty-seven patients who underwent thyroid planar scintigraphy with both a low-energy, high-resolution (LEHR) collimator and a ME collimator were prospectively recruited using the same imaging protocol. Image quality, collimator sensitivity, and estimation of thyroid size were assessed between LEHR and ME collimators and were compared with thyroid ultrasonography as the gold standard. Results: Images acquired with the ME collimator demonstrated reduced scattered background noise, improved thyroid-to-background contrast, and increased sensitivity in the thyroid gland compared with images acquired by the LEHR collimator. Manual measurement of the thyroid length is more accurate using the ME collimator. Automatic estimation of the thyroid area using the same thyroid threshold is larger in ME collimator images than in LEHR collimator images. Conclusion: Compared with the LEHR collimator, the ME collimator generates cleaner 123I thyroid scintigraphy images with less background noise and has higher collimator sensitivity for thyroid imaging. Different thyroid thresholds should be used to estimate the thyroid area and volume between low and ME collimators.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
10:16Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT