Related Experiment Video
Updated: Oct 18, 2025

Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
Published on: May 23, 2025
Ultrasound guided cannulation of dialysis access
Ruben Iglesias1, Massimo Lodi2, Carolina Rubiella1
1Nephrology Department, Parc Taulí University Hospital, Parc Taulí Research and Innovation Institute (I3PT), Autonomous University of Barcelona, Barcelona, Spain.
Doppler ultrasound (DU) can improve arteriovenous fistula (AVF) cannulation in haemodialysis (HD) by guiding needle placement, reducing complications compared to traditional methods. Proper training is essential for effective use of this advanced technique.
Area of Science:
- Nephrology
- Medical Imaging
- Vascular Access Procedures
Background:
- Arteriovenous fistula (AVF) is the preferred vascular access for haemodialysis (HD) due to lower mortality and fewer complications than central venous catheters (CVC).
- Despite AVF preference, cannulation complications can increase patient morbidity.
- Doppler ultrasound (DU) is recommended for AVF surveillance and shows promise for improving cannulation techniques.
Purpose of the Study:
- To evaluate the utility of Doppler ultrasound (DU) in arteriovenous fistula (AVF) cannulation for haemodialysis (HD).
- To compare ultrasound-guided needling with traditional 'blind' needling methods.
- To highlight the importance of training for effective implementation of ultrasound-guided AVF needling.
Main Methods:
- Review of Doppler ultrasound (DU) applications in AVF cannulation.
- Description of two primary ultrasound-assisted needling techniques: US-guided mapping and real-time US-guided needling (in-plane and out-of-plane approaches).
- Emphasis on essential recommendations for safe and reproducible procedures.
Main Results:
- Ultrasound-guided needling improves cannulation outcomes and reduces complications compared to blind techniques.
- Doppler ultrasound (DU) facilitates precise vessel mapping and needle insertion site identification.
- Real-time ultrasound guidance allows for simultaneous probe manipulation and needle insertion.
Conclusions:
- Doppler ultrasound (DU) is a valuable tool for enhancing AVF cannulation in haemodialysis (HD), leading to better results and fewer complications.
- Successful implementation requires specialized, long-term training for nursing staff to master the techniques and safety protocols.
- Ultrasound-guided needling offers significant potential for improving patient care and procedural efficiency in HD vascular access management.
Related Concept Videos
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications
Hemodialysis III: Nursing Management
Imaging Studies VII: Vascular Imaging
Imaging Studies II: Ultrasonography
Peritoneal Dialysis I: Introduction and Procedure