Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Diagnostic accuracy of multiplex polymerase chain reaction on tissue biopsies in periprosthetic joint infections
Igor Lazic1, Susanne Feihl2, Peter M Prodinger3
1Department of Orthopaedic Surgery, School of Medicine, Klinikum rechts der Isar, Klinik für Orthopädie und Sportorthopädie, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany. igor.lazic@mri.tum.de.
Abstract:
The diagnosis and treatment of periprosthetic joint infection (PJI) currently relies on cultures, which are time-consuming and often fail. Multiplex PCR assays promise reliable and prompt results, but have been heterogeneously evaluated. In this study, we analyse multiplex PCR in pathogen identification using only tissue biopsies. 42 patients after revision arthroplasty of the hip or knee were evaluated using multiplex PCR to identify microorganisms. The patients were classified according to the diagnostic criteria published by Zimmerli et al. and the results were compared to the respective microbiological cultures. PJI was detected in 15 patients and 27 revisions were aseptic. The multiplex PCR of tissue biopsies had a sensitivity of 0.3 (95% CI 0.12-0.62), a specificity of 1.0 (0.87-1.0), a positive predictive value of 1.0 (0.48-1.0) and a negative predictive value of 0.73 (0.56-0.86). The diagnostic accuracy of multiplex PCR on tissue biopsy samples is low in comparison to routine microbiological cultures. The evaluation of tissue biopsies using multiplex PCR was prone to false negative results. However, multiplex PCR assays have the advantage of rapid pathogen identification. We therefore recommend further investigation of multiplex PCR in the setting of suspected PJI with a careful choice of specimens.
Insights
Multiplex PCR on tissue biopsies for periprosthetic joint infection (PJI) shows low diagnostic accuracy and high false-negative rates compared to cultures. Further research is needed for rapid PJI pathogen identification.
Area of Science:
- Orthopedic Surgery
- Infectious Disease Diagnostics
- Molecular Microbiology
Background:
- Periprosthetic joint infection (PJI) diagnosis relies on slow, often unreliable cultures.
- Multiplex PCR offers rapid pathogen identification but requires thorough evaluation.
Purpose of the Study:
- To evaluate the diagnostic accuracy of multiplex PCR on tissue biopsies for PJI.
- To compare multiplex PCR results with microbiological cultures in revision arthroplasty patients.
Main Methods:
- Multiplex PCR was used to identify microorganisms in tissue biopsies from 42 patients undergoing hip or knee revision arthroplasty.
- Results were compared against standard microbiological cultures and classified using Zimmerli criteria.
Main Results:
- Multiplex PCR demonstrated low sensitivity (0.3) but high specificity (1.0) for PJI detection.
- The assay showed a high rate of false-negative results, leading to low overall diagnostic accuracy compared to cultures.
Conclusions:
- Multiplex PCR on tissue biopsies has limited diagnostic accuracy for PJI due to false negatives.
- Despite limitations, the rapid identification capability warrants further investigation with optimized specimen selection for suspected PJI.