Related Experiment Video
Updated: Oct 18, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
The Cost-Effectiveness of an Advanced Hybrid Closed-Loop System in People with Type 1 Diabetes: a Health Economic
Johan Jendle1, M I Buompensiere2, A L Holm3
1Institute of Medical Sciences, Campus USÖ, Örebro University, 701 82, Örebro, Sweden. johan.jendle@oru.se.
Introduction:
Swedish National Diabetes Registry data show a correlation of improved glycemic control in people with type 1 diabetes (T1D) with increased use of diabetes technologies over the past 25 years. However, novel technologies are often associated with a high initial outlay. The aim of the present study was to evaluate the long-term cost-effectiveness of the advanced hybrid closed-loop (AHCL) MiniMed 780G system versus intermittently scanned continuous glucose monitoring (isCGM) plus self-injection of multiple daily insulin (MDI) or continuous subcutaneous insulin infusion (CSII) in people with T1D in Sweden.
Methods:
Outcomes were projected over patients' lifetimes using the IQVIA CORE Diabetes Model (v9.0). Clinical data, including changes in glycated hemoglobin (HbA1c) and hypoglycemia rates, were sourced from observational studies and a randomized crossover trial. Modeled patients were assumed to receive the treatments for their lifetimes, with HbA1c kept constant following the application of treatment effects. Costs were accounted from a societal perspective and expressed in Swedish krona (SEK). Utilities and days off work estimates were taken from published sources.
Results:
The MiniMed 780G system was associated with an improvement in life expectancy of 0.16 years and an improvement in quality-adjusted life expectancy of 1.95 quality-adjusted life years (QALYs) versus isCGM plus MDI or CSII. These clinical benefits were due to a reduced incidence and a delayed time to onset of diabetes-related complications. Combined costs were estimated to be SEK 727,408 (EUR 72,741) higher with MiniMed 780G, with treatment costs partially offset by direct cost savings from the avoidance of diabetes-related complications and indirect cost savings from the avoidance of lost workplace productivity. The MiniMed 780G system was associated with an incremental cost-effectiveness ratio of SEK 373,700 per QALY gained.
Conclusions:
Based on a willingness-to-pay threshold of SEK 500,000 per QALY gained, the MiniMed 780G system was projected to be cost-effective versus isCGM plus MDI or CSII for the treatment of T1D in Sweden.
Related Concept Videos
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Type 2 and Gestational
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...
Diabetes: Symptoms, Diagnosis, and Complications

