Background:
For nearly three years, the concerns regarding trace levels of N-nitrosamines in pharmaceuticals and the associated cancer risk have significantly expanded and are a major issue facing the global pharmaceutical industry. N-nitrosodimethylamine (NDMA) found in formulations of the popular anti-diabetic drug metformin is a prominent example. This has resulted in product recalls raising the profile within the media. Issues of method robustness, sample preparation and several unexpected sources of nitrosamine contamination have been highlighted as false positive risks. It has become apparent that the identification of the root causes of artefactual formation of nitrosamines must be identified to mitigate risk associated with the analysis.
Methods:
A comparison study between four laboratories, across three companies was designed, employing orthogonal mass spectrometric methods for the quantification of NDMA in two metformin immediate release (IR) formulations and one extended release (XR) formulation. These were 2x LC-MS/MS, GC-MS/MS and GC-HRMS.
Results:
Good agreement of results was obtained for the IR formulations. However, we measured higher concentrations of NDMA in the XR formulation using GC-MS/MS compared to LC-MS/MS. We could show that this was due to artefactual (in situ) formation of NDMA when samples were extracted with dichloromethane. Removal of dimethylamine (DMA) and nitrite from the extracted sample or the addition of a nitrosation scavenger are shown to be effective remedies. NDMA in situ formation was not observed in 10% MeOH or acetonitrile.
Conclusion:
Metformin pharmaceuticals contain traces of the API impurity DMA as well as inorganic nitrite from excipients. This can lead to artefactual formation of NDMA and hence false positive results if DCM is used for sample extraction. Similar artefacts are likely also in other pharmaceuticals if these contain the secondary amine precursor of the respective nitrosamine analyte.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
08:15Understanding the Changes in Mitochondrial Morphology through Dynamic and Three-dimensional Fluorescence Micrographs
Published on: August 15, 2025
Related Concept Videos
Therapeutic Drug Monitoring: Drug Analysis Methods
Oral Hypoglycemic Agents: Biguanides and Glitazones