Microstructural dependence of mechanical properties and their relationship in modern resin-based composite materials
Related Experiment Video
Updated: Oct 18, 2025

Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
1Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestr. 70, D-80336 Munich, Germany.
Objective:
The aim of the study was to determine the influence of the microstructure on the mechanical behavior of resin-based composites (RBC) with little variation in chemical composition, and to verify a possible mutual dependency.
Methods:
Four RBCs with similar chemical composition of fillers (Ba-Al-B-F-Si-glass, SiO2), but with different mean (0.7 µm to 1.8 µm) and maximum particle size values (5 µm to 20 µm) were selected. Fracture toughness/KIC was evaluated in an NTP (Notchless Triangular Prism) test. Flexural strength/FS and modulus/E were measured in a 3-point-bending test. A fractographic analysis determined the fracture mode and origin. Quasi-static and viscoelastic parameters were assessed by a depth-sensing indentation test equipped with a DMA-module. One and multiple-way analysis of variance (ANOVA), Tukey honestly significant difference (HSD) post-hoc tests (α = 0.05), and Weibull statistics were applied.
Results:
The influence of the microstructure and the chemical composition of the organic matrix is weighted differently in the measured properties. The inorganic filler amount influences highest KIC (ηP2=0.813), followed by FS (ηP2=0.768) and E (ηP2=0.611). An optimized filler distribution with a high proportion of larger fillers up to 20 µm contributes to high FS and E data. The reliability of the material (Weibull parameter m) did not depend on the origin of fracture. Smaller inorganic fillers and the addition of 1% larger pre-polymer fillers improve the fracture toughness. Analysed RBCs were well adapted to chewing frequencies.
Conclusions:
The properties of RBCs can be tuned by little variation in microstructure and monomer matrix.
Clinical Significance:
Reverse engineering of clinically successful materials can be used to better design future RBCs.
Related Concept Videos
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Hooke's Law