Related Experiment Video
Updated: Oct 18, 2025

Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
Outdoor performance of the black globe temperature sensor on a hot and humid tropical region
Juan A Acero1,2, Angela Dissegna2, Yon Sun Tan1
1CENSAM, Singapore-MIT Aliance for Reasearch and Tecnology (SMART), Singapore, Singapore.
Abstract:
A crucial variable to evaluate thermal comfort is the mean radiant temperature (Tmrt). In this paper we evaluate the performance of the 150 mm black globe thermometer to provide reliable Tmrt values for outdoor settings in Singapore. Accurate Tmrt values are calculated by the method of integral radiation measurements. Based on these, the mean convection coefficient of the black globe has been re-calibrated. Results show an improvement in the estimation of Tmrt with the new coefficient in comparison with the default version suggested in ISO7726:1998. Increasing the averaging periods of the measured variables improved the performance of the derived mean convective coefficients to estimate Tmrt. During clear skies day and for 10-min averaged data, RMSE for Tmrt reduce to 3.9 °C (7.4 °C for ISO7726:1998 coefficient) with an overestimation on high incoming solar radiation periods and an underestimation during the morning and evening (low solar elevation). During overcast dry conditions an underestimation of Tmrt is also expected which is higher in the rain/wet periods. The mean convective coefficient presented in this work can provide improved estimations of Tmrt relevant for outdoor thermal comfort studies in hot and humid tropical climates like Singapore.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...