Related Experiment Video
Updated: Oct 18, 2025

Using Laser Scanning Microscopy to Determine Electromigration in Molybdenum Disilicide
Published on: May 23, 2025
Comparison of the Morse Cone Connection with the Internal Hexagon and External Hexagon Connections Based on
Ana Beatriz Bueno Carlini Bittencourt1, Clóvis Lamartine de Moraes Melo Neto1, Paulo Augusto Penitente1
1Department of Dental Materials and Prosthodontic, Araçatuba School of Dentistry, São Paulo State University (UNESP), São Paulo, Brazil.
Abstract:
The gap formed at the abutment-implant interface brings about a bacterial colonization. In addition, a bacterial reservoir can be established within the implant. The build-up of microorganisms around the implant can cause soft tissue infections and bone loss around the implant, which can lead to implant failure. Our literature review aimed to evaluate the infiltration at the implant-abutment interface, comparing the Morse cone connection with the external hexagon and internal hexagon connections. A literature search using the PubMed database was performed on March 24, 2021. The search terms were combinations of "Morse cone" or "Morse taper" with each of the following terms (individually): "microleakage", "leakage", "infiltration", and "penetration". The inclusion criterion was in vitro studies comparing the Morse cone with the external hexagon and/or internal hexagon, based on infiltration at the implant-abutment interface. The exclusion criterion was the evaluation of microleakage at the implant-abutment interface after applying a sealant over this region. The search was expanded as needed. There was no limit on the year of publication, and only articles written in English were included. In addition, references cited in included articles were also included in this review when they were appropriate. This literature review concluded that, in most cases, the microleakage in the Morse cone connection was lower when compared with the external hexagon and internal hexagon connections.
Related Concept Videos
Thin-Walled Hollow Shafts
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Design of Transmission Shafts
Inductance: Solid Cylindrical Conductor
Given the uniform current distribution, the magnetic field Hx and flux density Bx inside the conductor are...
Transmission Shafts: Problem Solving
Next, use bending moment diagrams for the shaft to...