Related Experiment Video
Updated: Oct 18, 2025

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
A novel electrochemical sensor for the determination of histidine based on a molecularly imprinted copolymer
Zahra Mirzaei Karazan1, Mahmoud Roushani1
1Department of Chemistry, Faculty of Sciences, Ilam University, P. O. Box, Ilam 69315-516, Iran. m.roushani@ilam.ac.ir.
Abstract:
The present study aimed to report a novel electrochemical sensor through electropolymerization of o-aminophenol (o-AP) and m-dihydroxy benzene (m-DB) as monomers on the surface of the glassy carbon electrode (GCE) for the determination of histidine (His) as a template molecule. The developed sensor exhibited satisfactory sensitivity and high selectivity, and also offered a linear range between 0.005 and 10.0 μM with a detection limit of 0.9 nM. Finally, it is worth mentioning that we also aimed at employing the proposed sensor for the detection of His in blood serum samples.