Related Experiment Video
Updated: Oct 18, 2025

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Initial Experiences of Percutaneous Coronary Intervention Using a New-Generation Everolimus-Eluting Stent Platform
Jonathan A Mailey1, Mahmoud Ahmed, Meadhbh Hogg
1Cardiology Department, Royal Victoria Hospital, 274 Grosvenor Road, Belfast, BT12 6BA. jonathan.mailey@belfasttrust.hscni.net.
The Synergy Megatron drug-eluting stent (DES) shows excellent short-term safety and effectiveness in percutaneous coronary intervention (PCI). This new DES technology achieved very low major adverse cardiovascular events, with no stent thrombosis or deformation observed.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Medical Device Technology
Background:
- The Synergy Megatron drug-eluting stent (DES) is a new platform with un reported outcomes.
- Percutaneous coronary intervention (PCI) is a common procedure for treating coronary artery disease.
Purpose of the Study:
- To evaluate the periprocedural outcomes of the Synergy Megatron DES in patients undergoing PCI.
- To assess the safety and effectiveness of this novel DES technology in a real-world setting.
Main Methods:
- A retrospective study of 139 patients undergoing PCI with the Synergy Megatron DES across two UK centers.
- Primary endpoint: cardiovascular death. Secondary endpoint: composite of non-fatal myocardial infarction, target-vessel revascularization, in-stent restenosis, and stent thrombosis.
- Post hoc analysis of intravascular ultrasound (IVUS) imaging to evaluate optimization criteria.
Main Results:
- Low rates of major adverse cardiovascular events (0.7% cardiovascular death, 0.0% secondary composite endpoint).
- No cases of longitudinal stent deformation (LSD) or acute/subacute stent thrombosis were reported.
- High rates of successful IVUS optimization achieved (74.1% in left main stem, 83.3% in right coronary artery).
- Mean minimal stent area (MSA) achieved across different coronary vessels.
Conclusions:
- The Synergy Megatron DES demonstrates very low short-term adverse events, including no LSD or stent thrombosis.
- The platform exhibits favorable overexpansion capabilities, facilitating IVUS-optimized stent parameters.
- This technology is safe and effective for treating large proximal vessels and bifurcations.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Acute Coronary Syndrome III: Diagnostic Studies
Cardiac Catheterization IV: Nursing Management
Acute Coronary Syndrome I: Introduction