Non-invasive capnodynamic mixed venous oxygen saturation during major changes in oxygen delivery
Anders Svedmyr1,2, Mark Konrad3, Mats Wallin1,3
1Karolinska Institute Department of Physiology and Pharmacology (FYFA), C3, Per-Arne Lönnqvist Group - Section of Anesthesiology and Intensive Care, Anestesi- och Intensivvårdsavdelningen, 171 76, Stockholm, PA, Sweden.
Abstract:
Mixed venous oxygen saturation (SvO2) is an important variable in anesthesia and intensive care but currently requires pulmonary artery catheterization. Recently, non-invasive determination of SvO2 (Capno-SvO2) using capnodynamics has shown good agreement against CO-oximetry in an animal model of modest hemodynamic changes. The purpose of the current study was to validate Capno-SvO2 against CO-oximetry during major alterations in oxygen delivery. Furthermore, evaluating fiberoptic SvO2 for its response to the same challenges. Eleven mechanically ventilated pigs were exposed to oxygen delivery changes: increased inhaled oxygen concentration, hemorrhage, crystalloid and blood transfusion, preload reduction and dobutamine infusion. Capno-SvO2 and fiberoptic SvO2 recordings were made in parallel with CO-oximetry. Respiratory quotient, needed for capnodynamic SvO2, was measured by analysis of mixed expired gases. Agreement of absolute values between CO-oximetry and Capno-SvO2 and fiberoptic SvO2 respectively, was assessed using Bland-Altman plots. Ability of Capno- SvO2 and fiberoptic SvO2 to detect change compared to CO-oximetry was assessed using concordance analysis. The interventions caused significant hemodynamic variations. Bias between Capno-SvO2 and CO-oximetry was + 3% points (95% limits of agreements - 7 to + 13). Bias between fiberoptic SvO2 and CO-oximetry was + 1% point, (95% limits of agreements - 7 to + 9). Concordance rate for Capno-SvO2 and fiberoptic SvO2 vs. CO-oximetry was 98% and 93%, respectively. Capno-SvO2 generates absolute values close to CO-oximetry. The performance of Capno-SvO2 vs. CO-oximetry was comparable to the performance of fiberoptic SvO2 vs. CO-oximetry. Capno-SvO2 appears to be a promising tool for non-invasive SvO2 monitoring.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...