A back table ultraviolet light decreases environmental contamination during operative cases
Jason M Jennings1, Todd M Miner2, Roseann M Johnson2
1Colorado Joint Replacement, Denver CO; Department of Biomedical Engineering, University of Denver, Denver, CO.
Background:
The purpose of this study is to assess the impact of a germicidal ultraviolet light-emitting diode (LED) on the contamination level of a back table in the operating room (OR) during total joint arthroplasty procedures.
Methods:
Eight Tryptic Soy Agar petri plates were placed on a table located near the operative field and exposed to air. One plate was removed on the hour over an 8-hour time span. The back table had either an UV-LED for disinfection or a sham UV-LED. This process was repeated in 12 different ORs (6 with UV light, 6 with sham device). The plates were then incubated for 48 hours at 36°C ± 1°C . Colony forming units (CFU) were recorded 24 and 48 hours after incubation.
Results:
There was a statistically significant difference in total CFUs between the intervention vs sham at 24-hours (27 vs 95, P = .0001) and 48-hours (38 vs 122, P < .0001). The multivariate analysis revealed that the 24-hour and 48-hour count, the predictors UV light (P = .002) and hour of plate removal (P = .050) were statistically significantly associated with CFU counts. Together, the predictor variables explained 15.8% and 23.0% of the variance in CFU counts at 24- and 48-hours, respectively.
Conclusions:
A back table UV-LED may decrease environmental contamination near the operative field. This has potential to lead to a decrease in joint infection.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Hand hygiene
Hand washing...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...