The Coulter Principle: A history
1Nicholasville, Kentucky, USA.
Summary
This paper introduces the factual history of Wallace H. Coulter's invention of blood cell analysis instrumentation. It details the developmental process based on exclusive access to personal and family archives.
Area of Science:
- Biomedical Engineering
- Medical Technology
- Scientific Instrumentation
Background:
- Historical accounts of Wallace H. Coulter's inventions have been scarce and often speculative.
- A recent history thesis provides the first factual, detailed account of Coulter's developmental process.
Related Concept Videos
Coulomb's Law and The Principle of Superposition
10.0K
Coulomb's Law describes the force experienced by two point charges under each other's presence. But what if there are more than two charges? For example, if there is a third charge, does it experience a force that is a simple combination of the individual forces due to the first two charges? Can it be described mathematically?
The Principle of Superposition answers the question. Yes, Coulomb's Law applies to each pair of charges, and the net force on each charge is the vector sum of...
The Principle of Superposition answers the question. Yes, Coulomb's Law applies to each pair of charges, and the net force on each charge is the vector sum of...
10.0K
Coulometry: Overview
1.7K
Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
1.7K
Controlled-Current Coulometry: Overview
380
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
380
Controlled-Potential Coulometry: Electrolytic Methods
343
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
343
Controlled-Current Coulometry: Coulometric Titration
277
Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
277
Superposition Theorem
997
The superposition principle is a fundamental concept stating that in a linear circuit, the voltage across (or current through) an element can be determined by summing the individual contributions of each independent source acting in isolation. When dealing with linear circuits containing multiple independent sources, this principle serves as a valuable tool for analysis. To apply the superposition principle effectively, one should focus on a single independent source at a time while...
997