Snapshot spectroscopic Mueller matrix polarimetry based on spectral modulation with increased channel bandwidth
Abstract:
This paper presents a snapshot spectroscopic Mueller matrix polarimetry based on spectral modulation. The polarization state generator consists of a linear polarizer in front of two high-order retarders, and the polarization state analyzer is formed by two non-polarization beam splitters incorporated with three high-order retarder/linear analyzer pairs. It can simultaneously generate three modulated spectra used for reconstructing the 16 spectroscopic Mueller elements of the sample. Since each of the modulated spectra produces seven separate channels equally spaced in the Fourier domain, the channel bandwidth can be enhanced efficiently compared with the conventional spectrally modulated spectroscopic Mueller matrix polarimetry. The feasibility of the proposed spectroscopic Mueller matrix polarimetry is demonstrated by the experimental measurement of an achromatic quarter-wave plate.
More Related Videos
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
08:49Author Spotlight: Unveiling the Potential of VSFG Microscopy in Studying Mesoscopically Heterogeneous Self-Assembled Structures
Published on: December 1, 2023
Related Concept Videos
UV–Vis Spectroscopy: Molecular Electronic Transitions
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration