Related Experiment Video
Updated: Oct 17, 2025

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Suture Tape Augmentation of Screw Fixation Reduces Fragment Migration in Tibial Tubercle Osteotomy: A Biomechanical
Mark Frame1, Oliver Hauck2, Michael Newman1
1Trauma and Orthopaedics, University Hospital Southampton, Southampton, UK.
Background:
Tibial tubercle osteotomy (TTO) is a complex surgical procedure with a significant risk of complications, which include nonunion and tibial fracture.
Purpose:
To determine whether an additional suture tape augmentation can provide better biomechanical stability compared with standard screw fixation.
Study Design:
Controlled laboratory study.
Methods:
Five matched pairs of human cadaveric knees were divided into 2 groups: the first group underwent standard TTO fixation with 2 parallel screws (standard group). The second group underwent a novel fixation technique, in which a nonabsorbable suture tape (FiberTape) in a figure-of-8 construct was added to the standard screw fixation for extra stabilization in the inferior-superior direction (augmented group). The specimens were biomechanically tested using a multistep cyclic loading protocol from 400 N up to 800 N to simulate the rehabilitation process. Tubercular fragment migration of >50% of the initial distalization length was defined as clinical failure. A pull-to-failure test was applied to the specimens that survived cyclic loading. Tubercular fragment displacement during cyclic loading and pull-to-failure force were recorded and compared between the 2 groups.
Results:
Two specimens of the standard group exhibited clinical failure during cyclic loading to 400 N. All other specimens survived cyclic loading to 800 N. The augmented group showed less cyclic tubercular fragment displacement after every load level compared with the standard group, with statistically significant differences starting from 500 N (P < .05; power > 0.8). Mean ± standard deviation tubercular fragment displacement at the end of cyclic loading was 2.56 ± 0.82 mm for the augmented group and 5.21 ± 0.51 mm for the standard group. Mean ultimate failure load after the pull-to-failure test was 2475 ± 554 N for the augmented group and 1475 ± 280 N for the standard group.
Conclusion:
The specimens that underwent suture tape augmentation showed less tubercular fragment displacement during cyclic loading and higher ultimate failure forces compared with those that underwent standard screw fixation.
Clinical Relevance:
The augmentation technique could potentially increase the success of a TTO.