Dandan Chu1, Li Yan1, Qiwen Chen1
1College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, PR China. chenxj@njtech.edu.cn.
Abstract:
Hollow prism-like NiCo2S4 materials (NiCo2S4 HNPs) were successfully fabricated by a two-step method. Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and powder X-ray diffraction (XRD) confirmed the morphology and structure of the as-prepared NiCo2S4 nanoprisms. A non-enzymatic sensor based on NiCo2S4 HNPs was constructed with outstanding electrochemical activity towards glucose oxidation in alkaline medium. The sensor showed a rapid response time (∼0.1 s), a high sensitivity of 82.9 μA mM-1 cm-2, a wide linear range (0.005-20.2 mM) and a detection limit of 0.8 μM (S/N = 3) with a good selectivity and reproducibility. Additionally, the proposed electrode also confirmed the feasibility in practical blood serum. These results indicate that NiCo2S4/ITO has great potential in the development of non-enzymatic glucose sensor applications.